D SUB SHELL, RECEPTACLE, SIZE 2, STEEL

5749246-1

Manufacturer Part Number
5749246-1
Description
D SUB SHELL, RECEPTACLE, SIZE 2, STEEL
Manufacturer
TE Connectivity
Series
AMPLIMITE HDP-20r
Datasheets

Specifications of 5749246-1

Connector Type
D Sub
Connector Shell Size
2
Connector Body Material
Metal
Body Material
Steel
No. Of Contacts
15
Rohs Compliant
Yes
Product Type
Connector
Product Series
HDP-20 (Crimp Snap)
Mating Connector Lock
With
Mating Connector Lock Type
Slide Latches
Shell Size
2
Shell Type
Full Metal Shell
Grounding Indents
Without
Grade
Standard
Enclosure Material
PVC, Elastomer, Styrene polyolefin
Color
Black
Shell Material
Carbon Steel
Shield Material
Steel
Shielded
Yes
Number Of Positions
15
Pre-assembled
Yes
Cable Insulation Diameter (mm [in])
4.83 – 9.53 [0.190 – 0.375]
Shell Plating
Tin over Copper
Shield Plating
Tin over Copper
Insert Material
Nylon
Insert Flammability Rating
UL 94V-0
Locking Post Material
Brass
Locking Post Plating
Tin over matte Copper
Preloaded
No
Contact Size
20
Enclosure
With
Connector Style
Receptacle
Housing Material
Nylon
Ul Flammability Rating
UL 94V-0
Housing Color
Black
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
For Use With
HDP-20 Series D Sub Connectors
Tem perature rise vs current.
Vibration, random .
Mechanical shock.
Durability.
Mating force.
Unm ating force.
Contact insertion force.
Rev F
Test Description
30°C m axim um tem perature rise at
specified current.
No discontinuities of 1 m icrosecond
or longer duration.
See Note.
No discontinuities of 1 m icrosecond
or longer duration.
See Note.
See Note.
Size Posn
Size Posn
13.3 N [3 lbf] m axim um per contact. EIA-364-5.
1
2
3
4
5
1
2
3
4
5
15
25
37
50
15
25
37
50
9
9
Figure 1 (continued)
MECHANICAL
Requirem ent
12.5 [2.8]
20.9 [4.7]
34.7 [7.8]
51.6 [11.6] 177.9 [40]
69.4 [15.6] 195.7 [44]
12.5 [2.8]
20.9 [4.7]
34.7 [7.8]
51.6 [11.6] 177.9 [40]
69.4 [15.6] 195.7 [44]
(N [lbf] m axim um )
W ithout
(N [lbf] m axim um )
W ithout
Ground Indents
Ground Indents
133.4 [30]
146.8 [33]
164.6 [37]
133.4 [30]
146.8 [33]
164.6 [37]
W ith
W ith
EIA-364-70, Method 1.
Stabilize at a single current level
until 3 readings at 5 m inute intervals
are within 1°C.
See Figure 4.
EIA-364-28, Test Condition V,
Condition F.
Subject m ated specim ens to 20.71
G's rm s between 50 to 2000 Hz.
Fifteen m inutes in each of 3
m utually perpendicular planes.
See Figure 5.
EIA-364-27, Method A.
Subject m ated specim ens to 50 G's
half-sine shock pulses of 11
m illiseconds duration. Three shocks
in each direction applied along 3
m utually perpendicular planes, 18
total shocks.
See Figure 5.
EIA-364-9.
Mate and unm ate gold flash
specim ens for 100 cycles, and 30
ìin gold specim ens for 500 cycles
at a m axim um rate of 200 cycles
per hour.
EIA-364-13.
Measure force necessary to m ate
specim ens at a m axim um rate of
25.4 m m [1 in] per m inute.
EIA-364-13.
Measure force necessary to unm ate
specim ens at a m axim um rate of
25.4 m m [1 in] per m inute.
Measure force necessary to insert
contact into housing.
Procedure
108-40005
3 of 10

Related parts for 5749246-1