ACPL-P340-000E Avago Technologies US Inc., ACPL-P340-000E Datasheet - Page 4

no-image

ACPL-P340-000E

Manufacturer Part Number
ACPL-P340-000E
Description
Gate Drive Optocoupler, LF
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of ACPL-P340-000E

No. Of Channels
1
Optocoupler Output Type
Gate Drive
Input Current
16mA
Opto Case Style
SOIC
No. Of Pins
6
Leaded Process Compatible
Yes
Peak Reflow Compatible (260 C)
Yes
Rohs Compliant
Yes
Lead Free Status / Rohs Status
 Details
Recommended Pb-Free IR Profi le
Recommended refl ow condition as per JEDEC Standard, J-STD-020 (latest revision). Non- Halide Flux should be used.
Regulatory Information
The ACPL-P340/W340 is pending approval by the following organizations:
UL
Recognized under UL 1577, component recognition program up to V
(ACPL-W340) expected prior to product release.
CSA
CSA Component Acceptance Notice #5, File CA 88324
IEC/EN/DIN EN 60747-5-2 (Option 060 Only)
Maximum Working Insulation Voltage V
Table 1. IEC/EN/DIN EN 60747-5-2 Insulation Characteristics* (Option 060 – Under Evaluation)
*
Note:
These optocouplers are suitable for “safe electrical isolation” only within the safety limit data. Maintenance of the safety data shall be ensured by
means of protective circuits. Surface mount classifi cation is Class A in accordance with CECC 00802.
4
Description
Installation classifi cation per DIN VDE 0110/1.89, Table 1
Climatic Classifi cation
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
V
Partial discharge < 5 pC
Input to Output Test Voltage, Method a*
V
Partial discharge < 5 pC
Highest Allowable Overvoltage
(Transient Overvoltage t
Safety-limiting values – maximum values allowed in the event
of a failure.
Insulation Resistance at T
IORM
IORM
Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section, (IEC/EN/
DIN EN 60747-5-2) for a detailed description of Method a and Method b partial discharge test profi les.
for rated mains voltage ≤ 150 V
for rated mains voltage ≤ 300 V
for rated mains voltage ≤ 450 V
for rated mains voltage ≤ 600 V
for rated mains voltage ≤ 1000 V
Case Temperature
Input Current
Output Power
x 1.875 = V
x 1.6 = V
PR
, Type and Sample Test, t
PR
, 100% Production Test with t
ini
S
, V
= 60 sec)
IO
= 500 V
rms
rms
rms
rms
rms
m
= 10 sec,
IORM
m
= 891 V
= 1 sec,
peak
(ACPL-P340) and V
Symbol
V
V
V
V
T
I
P
R
S, INPUT
S
IORM
PR
PR
IOTM
S, OUTPUT
S
ISO
= 3750 V
IORM
ACPL-P340
Option 060
I – IV
I – IV
I – III
I – III
55/100/21
2
891
1671
1426
6000
175
230
600
>10
9
= 1140 V
RMS
(ACPL-P340) and V
peak
(ACPL-W340)
ACPL-W340
Option 060
I – IV
I – IV
I – IV
I – IV
I – III
55/100/21
2
1140
2137
1824
8000
175
230
600
>10
9
ISO
= 5000 V
Unit
V
V
V
V
°C
mA
mW
peak
peak
peak
peak
RMS

Related parts for ACPL-P340-000E