INT-1532-L-5-M-001=1 TE Connectivity, INT-1532-L-5-M-001=1 Datasheet - Page 6

DIGITAL PANEL METER, 4-DIGIT, 57.7V TO 139V / 100V TO 240V

INT-1532-L-5-M-001=1

Manufacturer Part Number
INT-1532-L-5-M-001=1
Description
DIGITAL PANEL METER, 4-DIGIT, 57.7V TO 139V / 100V TO 240V
Manufacturer
TE Connectivity
Datasheet

Specifications of INT-1532-L-5-M-001=1

No. Of Digits / Alpha
4
Meter Function
Digital
Meter Range
0mA To 20mA
Digit Height
96mm
Supply Voltage Range
57.7V To 139V / 100V To 240V
Power Consumption
3W
Programmable Parameters
Specifications
Parameter
Password:
CT primary current:
VT primary voltage:
VT secondary voltage:
Demand integration time:
3 independent resets:
Pulse output duration:
Pulse rate divisors:
RS485 baud rate:
RS485 parity and stop bits:
Input
Nominal input voltage:
Max. continuous input voltage:
Max. short duration input voltage:
System VT ratios (primary):
Nominal input voltage burden:
Nominal input current:
System CT primary values:
Max. continuous input current:
Max. short duration input current:
Nominal input current burden:
Outputs (optional)
RS485 communications:
Baud rates:
Pulsed:
Pulse duration:
Contact rating
Pulsed outputs:
Auxiliary
Standard nominal supply
voltage:
AC supply frequency range:
AC supply burden:
Optional auxiliary dc supply:
DC supply burden:
Range
4-digit 0000-9999
Maximum 9999A **
CT Secondary Current: 5A (1A option)
Maximum 400kV **
Nominal input voltage
** maximum VT or CT ratios are limited so
that the combination of primary voltage and
current do not exceed 360MW at 120% of
relevant input
8, 15, 20, 30, 60 minutes
Demands and maximum demands
Energy registers
Hours run
60, 100, 200 milliseconds
1, 10, 100, 1000
4.8, 9.6, 19.2, 38.4 kBd
Odd or even with 1 stop bit
or no parity with 1 or 2 stop bits
2-wire half duplex
4800, 9600, 19200, 38400
Solid state relays
60, 100 or 200 milliseconds
50mA max at 250V ac max.
1 or 2
100-250V ac or dc
(85-287V ac absolute limits)
(85-312V dc absolute limits)
45-66Hz
6VA
12-48V dc
(10.2-60V dc absolute limits)
6VA
Value
57.7 to 277V L-N, 100 to 480V L-L
120% nominal
2 x nominal for 1 second, repeated 10 times
at 10 second intervals
Any significant 4-digit integer value up to
400kV **
< 0.2 VA
5A (1A option)
Any integer value up to 9999A **
120% nominal
20 x nominal for 1 second, repeated 5 times
at 5 minute intervals
< 0.6 VA
** maximum CT and VT ratios are limited
so that the combination of primary voltage
and current do not exceed 360MW at 120%
of relevant input
Accuracy Defined
*Error in energy readings is expressed
Error change due to variation of an
influence quantity (except temperature)
by varying one influence quantity within
range of use, whilst keeping all other
influence quantities at their nominal
value is less than twice the error
allowed for the reference condition
applied in the test.
(This definition is applied to limit the
number of combinations to be applied
during type tests)
Error due to temperature variation is
as above.
Error in measurement when a
measurand is within its measuring
range, but outside its reference range
is less than twice the error allowed at
the end of the reference range adjacent
to the section of the measuring range
where the measurand is currently
operating / being tested.
*Error in energy readings is expressed
as a percentage of the energy count
that would result from applying range
maximum voltage and nominal current
for the same measurement period.
as a percentage of the energy count
that would result from applying a
range maximum voltage and nominal
current for the same measurement
period.