INT-1532-L-5-M-001=1 TE Connectivity, INT-1532-L-5-M-001=1 Datasheet - Page 17

DIGITAL PANEL METER, 4-DIGIT, 57.7V TO 139V / 100V TO 240V

INT-1532-L-5-M-001=1

Manufacturer Part Number
INT-1532-L-5-M-001=1
Description
DIGITAL PANEL METER, 4-DIGIT, 57.7V TO 139V / 100V TO 240V
Manufacturer
TE Connectivity
Datasheet

Specifications of INT-1532-L-5-M-001=1

No. Of Digits / Alpha
4
Meter Function
Digital
Meter Range
0mA To 20mA
Digit Height
96mm
Supply Voltage Range
57.7V To 139V / 100V To 240V
Power Consumption
3W
Measurement, Display and
Communication
Integra 2000 unit offers configuration,
display and configuration of up to 103
electrical and power quality parameters.
1
2
3
4
5
6
7
8
9
10 Maximum current (per phase)
11 Current demand
12 System frequency
13 System watts (sum)
14 Watts L1
15 Minimum watts (per phase)
16 Maximum watts (per phase)
17 VAr L1
18 Minimum VArs (per phase)
19 Maximum VArs (per phase)
20 VA L1
21 Minimum VA (per phase)
22 Maximum VA (per phase)
23 Power factor L1
24 Phase angle L1
25 KWh import (8-digit resolution)
26 kW demand (import)
16
System volts
System amps
Frequency
System kW
Volts L1-N (4-wire only)
Volts L2-N (4-wire only)
Volts L3-N (4-wire only)
Volts L-N (average)
Minimum volts L-N (per phase)
Maximum volts L-N (per phase)
Volts L1-L2
Volts L2-L3
Volts L3-L1
Volts L-L (average)
Minimum volts L-L (per phase)
Maximum volts L-L (per phase)
Current L1
Current L2
Current L3
Current (average)
Minimum current (per phase)
Current maximum demand
Minimum frequency
Maximum frequency
System VArs (sum)
System VA (sum)
Power factor sys
Watts L2
Watts L3
Watts sum
VAr L2
VAr L3
VAr sum
VA L2
VA L3
VA sum
Power factor L2
Power factor L3
Power factor sys
Phase angle L2
Phase angle L3
Phase angle sys
KWh export (8-digit resolution)
KVArh import (8-digit resolution)
KVArh export (8-digit resolution)
VAh (8-digit resolution)
Ah(8-digit resolution)
kW maximum demand (import)
kW demand (export)
kW maximum demand (export)
Programmable Parameters
Product Codes
Parameter
Password:
Primary current:
VT primary:
** maximum VT or CT ratios are limited so that the combination of primary voltage
and current does not exceed 999MW at 120% of relevant input
Reset:
Demand integration time:
Demand sub-intervals
RS485 interface baud rate:
RS485 parity:
Stop bits:
Modbus address:
Analogue output assignment:
Pulse output assignment:
Pulse rate divisors:
Pulse output duration:
User screen:
Display update rate (override):
Product code
244-INMW-*-**
Input voltage suffix *
VUA2
QPA2
BFA2
PQA2
VUA5
QPA5
BFA5
PQA5
Product code
244-INWW-*-**
Input voltage suffix *
VQA2
VRA2
QSA2
RSA2
PGA2
QYA2
VQA5
VRA5
QSA5
RSA5
PGA5
QYA5
Communication options**
000000
4800P2
48A2P2
JC00P2
JCA2P2
LN0000
Order Code Example
244-INWW-VRA2-4800P2 - Integra 2000 3-phase 4-wire, input 230V L-N nominal
voltage, 5A CT input, 100-250V ac/dc auxiliary, with RS485 Modbus and two pulse
relay outputs.
Range
4-digit 0000-9999
Max 999.9kA (999MW max**)
999.9kV (999MW max**)
Individual energy registers, minimum and
maximum registers, demand registers
1-30 minutes
1-30 minutes
2.4, 4.8, 9.6, 19.2 kB
Odd, even, none
1, 2
1-247
Pick list of 44 measured parameters
Import kWh, export kWh, import VArh,
export VArh, VAh, Amph, none
1, 10, 100, 1000
20-200 milliseconds
4 lines, choice of 42 measured parameters
1-20
Product configuration
Integra 2000 3-phase 3-wire, 5A CT input
100V L-L input, 100-250V ac/dc auxiliary
110V L-L input, 100-250V ac/dc auxiliary
115V L-L input, 100-250V ac/dc auxiliary
120V L-L input, 100-250V ac/dc auxiliary
100V L-L input, 12-48V dc auxiliary
110V L-L input, 12-48V dc auxiliary
115V L-L input, 12-48V dc auxiliary
120V L-L input, 12-48V dc auxiliary
Product configuration
Integra 2000 3-phase 4-wire, 5A CT input
220V L-N input, 100-250V ac/dc auxiliary
230V L-N input, 100-250V ac/dc auxiliary
240V L-N input, 100-250V ac/dc auxiliary
250V L-N input, 100-250V ac/dc auxiliary
254V L-N input, 100-250V ac/dc auxiliary
277V L-N input, 100-250V ac/dc auxiliary
220V L-N input, 12-48V dc auxiliary
230V L-N input, 12-48V dc auxiliary
240V L-N input, 12-48V dc auxiliary
250V L-N input, 12-48V dc auxiliary
254V L-N input, 12-48V dc auxiliary
277V L-N input, 12-48V dc auxiliary
No outputs
RS485 Modus, 2 pulse relays
RS485, 4 x 4/20mA analogue outputs,
2 pulse relays
RS485 Johnson Controls, 2 pulse outputs
RS485 Johnson Controls, 4 x 4/20mA
analogue outputs, 2 pulse relays
Lonworks interface

Related parts for INT-1532-L-5-M-001=1