X9221WP Intersil, X9221WP Datasheet - Page 7

IC DCP DUAL 10K 64TP 20DIP

X9221WP

Manufacturer Part Number
X9221WP
Description
IC DCP DUAL 10K 64TP 20DIP
Manufacturer
Intersil
Series
XDCP™r
Datasheet

Specifications of X9221WP

Taps
64
Resistance (ohms)
10K
Number Of Circuits
2
Temperature Coefficient
30 ppm/°C Typical
Memory Type
Non-Volatile
Interface
I²C, 2-Wire Serial
Voltage - Supply
4.5 V ~ 5.5 V
Operating Temperature
0°C ~ 70°C
Mounting Type
Through Hole
Package / Case
20-DIP (0.300", 7.62mm)
Resistance In Ohms
10K
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
X9221WP
Manufacturer:
Intersil
Quantity:
1 500
Part Number:
X9221WP
Manufacturer:
XILINX
0
Part Number:
X9221WP
Manufacturer:
XICOR
Quantity:
20 000
Company:
Part Number:
X9221WP
Quantity:
200
X9221
DETAILED OPERATION
Both XDCP potentiometers share the serial interface
and share a common architecture. Each potentiometer
is comprised of a resistor array, a wiper counter regis-
ter and four data registers. A detailed discussion of the
register organization and array operation follows.
Wiper Counter Register
The X9221 contains two wiper counter registers
(WCR), one for each XDCP potentiometer. The WCR
can be envisioned as a 6-bit parallel and serial load
counter with its outputs decoded to select one of sixty-
four switches along its resistor array. The contents of
the WCR can be altered in four ways: it may be written
directly by the host via the Write WCR instruction
(serial load); it may be written indirectly by transferring
the contents of one of four associated data registers
via the XFR Data Register instruction (parallel load); it
can be modified one step at a time by the Increment/
Decrement instruction; finally, it is loaded with the con-
tents of its data register zero (R0) upon power-up.
Figure 8. Detailed Potentiometer Block Diagram
REV 1.1 8/8/02
Serial Data Path
From Interface
If WCR = 3F[H] then V
If WCR = 00[H] then V
Circuitry
W
W
/R
/R
W
W
= V
= V
Register 0
Register 2
H
L
/R
/R
L
H
8
Register 1
Register 3
www.xicor.com
Modified SCL
UP/DN
6
The WCR is a volatile register; that is, its contents are
lost when the X9221 is powered-down. Although the
register is automatically loaded with the value in R0
upon power-up, it should be noted this may be different
from the value present at power-down.
Data Registers
Each potentiometer has four nonvolatile data registers.
These can be read or written directly by the host and
data can be transferred between any of the four data
registers and the WCR. It should be noted all opera-
tions changing data in one of these registers is a non-
volatile operation and will take a maximum of 10ms.
If the application does not require storage of multiple
settings for the potentiometer, these registers can be
used as regular memory locations that could possibly
store system parameters or user preference data.
Serial
Bus
Input
Parallel
Bus
Input
UP/DN
CLK
Register
Counter
Wiper
INC/DEC
Logic
Characteristics subject to change without notice.
C
o
u
n
e
D
r
e
o
d
e
t
c
V
V
V
H
L
W
/R
/R
/R
7 of 15
L
H
W

Related parts for X9221WP