IMB06CGR TE Connectivity, IMB06CGR Datasheet

RELAY, SPST, NO, 12V, HI DIELECTRIC

IMB06CGR

Manufacturer Part Number
IMB06CGR
Description
RELAY, SPST, NO, 12V, HI DIELECTRIC
Manufacturer
TE Connectivity
Datasheet

Specifications of IMB06CGR

Coil Type
DC, Sensitive
Contact Configuration
SPST-NO
Contact Current Max
2A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
220V
Coil Voltage Vdc Nom
12V
Coil Resistance
1.029kohm
Coil
RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IMB06CGR
Manufacturer:
RAMTRON
Quantity:
938
IM Series
AXICOM Signal and Telecom Relays

Related parts for IMB06CGR

IMB06CGR Summary of contents

Page 1

IM Series AXICOM Signal and Telecom Relays ...

Page 2

AXICOM Telecom, Signal and RF Relays IM Relay UL 508 File No. E 111441 UL 60950 IEC/EN60950 IEC Ref. Cert. No. 3270 All specifications subject to change. Consult Tyco Electronics for latest specifications. Disclaimer While Tyco Electronics and its affiliates ...

Page 3

AXICOM Telecom, Signal and RF Relays IM Relay IM Relay 1 and 2 pole telecom/signal relay, polarized Through Hole Types (THT), standard version with 5.08 mm, narrow with 3.2 mm between the terminal rows or Surface Mount Type (SMT) Relay ...

Page 4

AXICOM Telecom, Signal and RF Relays IM Relay Selection Guide IM-A IM-B 1 Pole break 1 Pole make 1 Form B 1 Form A SPST NC SPST NO IM-A High Dielectric “C” Relay Code IM All specifications subject to change. ...

Page 5

AXICOM Telecom, Signal and RF Relays IM Relay 2 Pole Changeover / 2 Form C / DPDT Dimensions IM THT Standard mm inch L 10.00 ± 0.08 0.393 ± 0.003 W 6.00 ± 0.08 0.236 ± 0.003 H 5.65 – ...

Page 6

AXICOM Telecom, Signal and RF Relays IM Relay 2 Pole Changeover / 2 Form C / DPDT Coil Data (values at 23 °C) Nominal Operate/set voltage range voltage U nom Minimum Maximum voltage U voltage U min Vdc Vdc Standard ...

Page 7

AXICOM Telecom, Signal and RF Relays IM Relay 2 Pole Changeover / 2 Form C / DPDT Coil Data (values at 23 °C) Nominal Operate/set voltage range voltage U nom Minimum Maximum voltage U voltage U min Vdc Vdc Latching ...

Page 8

AXICOM Telecom, Signal and RF Relays IM Relay 2 Pole Changeover / 2 Form C / DPDT Coil Data (values at 23 °C) Nominal Operate/set voltage range voltage U nom Minimum Maximum voltage U voltage U min Vdc Vdc High ...

Page 9

AXICOM Telecom, Signal and RF Relays IM Relay 2 Pole Changeover / 2 Form C / DPDT Coil Data (values at 23 °C) Nominal Operate/set voltage range voltage U nom Minimum Maximum voltage U voltage U min Vdc Vdc Ultra ...

Page 10

AXICOM Telecom, Signal and RF Relays IM-A Relay 1 Pole Break / 1 Form B / SPST NC Dimensions IM-A THT Version Standard Version Mounting Hole Layout View onto the ...

Page 11

AXICOM Telecom, Signal and RF Relays IM-A Relay 1 Pole Break / 1 Form B / SPST NC Coil Data (values at 23 °C) Nominal Operate/set voltage range voltage U nom Minimum Maximum voltage U voltage U min Vdc Vdc ...

Page 12

AXICOM Telecom, Signal and RF Relays IM-B Relay 1 Pole Make / 1 Form A / SPST NO Dimensions IM-B THT Version Standard Version Mounting Hole Layout View onto the ...

Page 13

... Further coil versions are available on request. 108-98001 Rev. K Ordering Information Coil Relay Resistance code Ω / ± IMB01CGR 145 IMB02CGR 178 IMB03CGR 257 IMB04CGR 1029 IMB06CGR 2880 IMB07CGR 1-1462041-3 64 IMB01CTS 145 IMB02CTS 178 IMB03CTS 1029 IMB06CTS 2880 IMB07CTS 1-1462041-4 Tyco Electronics part ...

Page 14

AXICOM Telecom, Signal and RF Relays IM-C Relay 1 Pole Changeover / 1 Form C / SPDT Dimensions IM-C THT Version Standard Version Mounting Hole Layout View onto the component ...

Page 15

AXICOM Telecom, Signal and RF Relays IM-C Relay 1 Pole Changeover / 1 Form C / SPDT Coil Data (values at 23 °C) Nominal Operate/set voltage range voltage U nom Minimum Maximum voltage U voltage U min Vdc Vdc IM-C ...

Page 16

AXICOM Telecom, Signal and RF Relays IM-D Relay 2 Pole Break / 2 Form B / DPST NC Dimensions IM-D THT Version Standard Version Mounting Hole Layout View onto the ...

Page 17

AXICOM Telecom, Signal and RF Relays IM-D Relay 2 Pole break / 2 Form B / DPST NC Coil Data (values at 23 °C) Nominal Operate/set voltage range voltage U nom Minimum Maximum voltage U voltage U min Vdc Vdc ...

Page 18

AXICOM Telecom, Signal and RF Relays IM-E Relay 2 Pole Make / 2 Form A / DPST NO Dimensions IM-E THT Version Standard Version Mounting Hole Layout View onto the ...

Page 19

AXICOM Telecom, Signal and RF Relays IM-E Relay 2 Pole Make / 2 Form A / DPST NO Coil Data (values at 23 °C) Nominal Operate/set voltage range voltage U nom Minimum Maximum voltage U voltage U min Vdc Vdc ...

Page 20

AXICOM Telecom, Signal and RF Relays IM Relay 2 Pole Changeover / 2 Form C / DPDT Contact Data Number of contacts and type Contact assembly Contact material Limiting continuous current at max. ambient temperature Maximum switching current Maximum swichting ...

Page 21

AXICOM Telecom, Signal and RF Relays IM Relay Contact Data Number of contacts and type Contact assembly Contact material Limiting continuous current at max. ambient temperature Maximum switching current Maximum swichting voltage Maximum switching capacity Thermoelectric potential Minimum switching voltage ...

Page 22

AXICOM Telecom, Signal and RF Relays IM Relay Insulation IM Versions Insulation resistance at 500 Vdc Dielectric test voltage (1 min) between coil and contacts between adjacent contact sets between open contacts Surge voltage resistance according to Telcordia TR-NWT-001089 (2/10 ...

Page 23

AXICOM Telecom, Signal and RF Relays IM Relay High Frequency Data Capacitance between coil and contacts between adjacent contact sets between open contacts RF Characteristics Isolation at 100 MHz / 900 MHz Insertion loss at 100 MHz / 900 MHz ...

Page 24

AXICOM Telecom, Signal and RF Relays IM Relay Coil Operating Range 3.4 3 max. 2.8 2 2.4 max. 2 max. 1.6 ...

Page 25

AXICOM Telecom, Signal and RF Relays IM Relay Recommended Soldering Conditions Soldering conditions according IEC 60058-2-58 and IPC/JEDEC J-STD-020B sec 240 °C 180 °C 130 °C 100 °C Time (s) Recommended Reflow Soldering Profile Time (s) Resistance ...

Page 26

AXICOM Telecom, Signal and RF Relays IM Relay Packing Reel Dimension All specifications subject to change. Consult Tyco Electronics for latest specifications. 108-98001 Rev. K Dimensions in mm Tube for THT version 50 relays per tube 1‘000 relays per box ...

Page 27

AXICOM Telecom, Signal and RF Relays IM Relay IM Relays 4th generation slim line – low profile polarized 2 c/o telecom signal relay with bifurcated contacts, available as non latching or latching relay with 1 coil. Nominal voltage range from ...

Page 28

Tyco Electronics Corporation POB 3608, Harrisburg, PA 17105 USA Phone +1 800-522-6752 www.tycoelectronics.com 108-98001 • Jul. 09 Rev. K • ECOC: JM10 Tyco Electronics Logistics AG Werk Axicom Au Seestrasse 295 CH-8804 Au-Wädenswil / Switzerland Phone +41 44 782 91 ...