IM47GR TE Connectivity, IM47GR Datasheet

RELAY, SMD, DPCO, 24VDC

IM47GR

Manufacturer Part Number
IM47GR
Description
RELAY, SMD, DPCO, 24VDC
Manufacturer
TE Connectivity
Datasheet

Specifications of IM47GR

Coil Type
DC
Contact Configuration
DPCO
Contact Current Max
2A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
220V
Coil Voltage Vdc Nom
24V
Coil Resistance
2.88kohm
Coil Power Cont
200mW
Relay
RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IM47GR
Quantity:
5
AXICOM
Telecom-, Signal and RF Relays
IM Relay
108-98001 • Sep. 07 Rev. G • ECOC: JM10

Related parts for IM47GR

IM47GR Summary of contents

Page 1

IM Relay 108-98001 • Sep. 07 Rev. G • ECOC: JM10 AXICOM Telecom-, Signal and RF Relays ...

Page 2

AXICOM Telecom-, Signal and RF Relays IM Relay UL 508 File No. E 111441 UL 60950 IEC/EN60950 IEC Ref. Cert. No. 3270 All specifications subject to change. Consult Tyco Electronics for latest specifications. Disclaimer While Tyco Electronics has made every ...

Page 3

AXICOM Telecom-, Signal and RF Relays IM Relay Slim line AND low profile 2 pole telecom/signal relay, polarized Through Hole Types (THT), standard version with 5.08 mm, narrow version with 3.2 mm between the terminal rows or Surface Mount Type ...

Page 4

AXICOM Telecom-, Signal and RF Relays IM Relay Dimensions IM THT Standard mm inch L 10.00 ± 0.08 0.393 ± 0.003 W 6.00 ± 0.08 0.236 ± 0.003 H 5.65 – 0.20 0.222 – 0.008 T 3.2 0.125 T1 N/A ...

Page 5

AXICOM Telecom-, Signal and RF Relays IM Relay Coil Operating Range 3.4 3 max. 2.8 2 2.4 max. 2 max. 1.6 ...

Page 6

AXICOM Telecom-, Signal and RF Relays IM Relay Coil Data (values at 23 °C) Nominal Operate/set voltage range voltage U nom Minimum Maximum voltage U voltage U min Vdc Vdc Standard Version THT Standard non-latching 1 coil 1.5 1.13 3 ...

Page 7

... IM43JR 6-1462037-0 360 IM44JR 6-1462037-3 810 IM45JR 6-1462037-5 1440 IM46JR 6-1462037-8 2880 IM47JR 7-1462037-1 23 IM40GR 5-1462037-1 90 IM41GR 5-1462037-4 203 IM42GR 3-1462037-1 250 IM43GR 5-1462037-9 360 IM44GR 6-1462037-2 810 IM45GR 6-1462037-4 1440 IM46GR 6-1462037-7 2880 IM47GR 7-1462037-0 Tyco part number ...

Page 8

AXICOM Telecom-, Signal and RF Relays IM Relay Coil Data (values at 23 °C) Nominal Operate/set voltage range voltage U nom Minimum Maximum voltage U voltage U min Vdc Vdc High Sensitive Version SMT Gull Wings non-latching 1 coil 3 ...

Page 9

AXICOM Telecom-, Signal and RF Relays IM Relay Coil Data (values at 23 °C) Nominal Operate/set voltage range voltage U nom Minimum Maximum voltage U voltage U min Vdc Vdc Ultra High Sensitive Version SMT Gull Wings non-latching 1 coil ...

Page 10

AXICOM Telecom-, Signal and RF Relays IM Relay Contact Data Number of contacts and type Contact assembly Contact material Limiting continuous current at max. ambient temperature Maximum switching current Maximum swichting voltage Maximum switching capacity Thermoelectric potential Minimum switching voltage ...

Page 11

AXICOM Telecom-, Signal and RF Relays IM Relay Insulation Insulation resistance at 500 Vdc Dielectric test voltage (1 min) between coil and contacts between adjacent contact sets between open contacts Surge voltage resistance according to Telcordia TR-NWT-001089 (2/10 µs) between ...

Page 12

AXICOM Telecom-, Signal and RF Relays IM Relay Recommended Soldering Conditions Soldering conditions according IEC 60058-2-58 and IPC/JEDEC J-STD-020B sec 240 °C 180 °C 130 °C 100 °C Time (s) Recommended reflow soldering profile Time (s) Resistance ...

Page 13

AXICOM Telecom-, Signal and RF Relays IM Relay Packing Reel dimension All specifications subject to change. Consult Tyco Electronics for latest specifications. 108-98001 Rev. G Dimensions in mm Tube for THT version 50 relays per tube 1‘000 relays per box ...

Page 14

AXICOM Telecom-, Signal and RF Relays IM Relay IM Relays 4th generation slim line – low profile polarized 2 c/o telecom signal relay with bifurcated contacts, available as non latching or latching relay with 1 coil. Nominal voltage range from ...

Page 15

Tyco Electronics Logistics AG Werk Axicom Au Seestrasse 295 CH-8804 Au-Wädenswil / Switzerland Phone +41 44 782 91 11 Fax +41 44 782 90 00 E-mail: axicom@tycoelectronics.com Tyco Electronics Paulsternstrasse 26 D-13629 Berlin / Germany Phone +49 30 386 38573 ...