V23134A1052C643 TE Connectivity, V23134A1052C643 Datasheet - Page 3

AUTOMOTIVE RELAY, SPDT-CO, 12VDC, 40A

V23134A1052C643

Manufacturer Part Number
V23134A1052C643
Description
AUTOMOTIVE RELAY, SPDT-CO, 12VDC, 40A
Manufacturer
TE Connectivity
Datasheet

Specifications of V23134A1052C643

Coil Voltage Vdc Nom
12V
Contact Current Max
40A
Contact Voltage Dc Nom
12V
Coil Resistance
90ohm
Contact Configuration
SPDT
Relay Mounting
Plug In
External Height
24.9mm
Rohs Compliant
Yes
Contact Form
1 Form C (SPDT)
Coil Voltage
12 V
Contact Rating
40 A at 12 V
Coil Current
40 A
Lead Free Status / Rohs Status
 Details
34
Contact data
Contact configuration
Circuit symbol
(see also Pin assignment)
Rated voltage
Rated current at 85 °C
Contact material
Max. switching voltage/power
Max. switching current
On
Off
Min. recommended load
Voltage drop at 10 A (initial)
Mechanical endurance (without load)
Electrical endurance
(example of resistive load)
Max switching rate at nominal load
1)
2)
3)
4)
Load limit curve
Pin assignment
1 make contact/
1 form A
Special high performance 24 V version with contact gap > 0.8 mm, part number V23134-A0056-X432/-X433 (see ordering information).
See chapter Diagnostics in our Application Recommendations on page 18.
Models with resistor or
diode in parallel to the
coil on request.
The values apply to a resistive or inductive load with suitable spark suppression and at maximum 13.5 V for 12 V or 27 V for 24 V load voltages.
For a load current duration of maximum 3 s for a make/break ratio of 1:10.
2)
1)
4)
NO contact
NC contact
Plug-in relays
Mini ISO relays
Power relay F4
Power relay F4 only
1 double make contact/
1 form U
Models with resistor or
diode in parallel to the
coil on request.
operations
40 A, 14 V
> 2 x 10
120 A
12 V
40 A
60 A
Typ. 15 mV, 200 mV max.
Form A or Form A (2x87)
Make contact/
5
AgNi0.15
or
operations
20 A, 28 V
> 1 x 10
Please observe the disclaimer.
120 A
24 V
20 A
20 A
5
*)
2 x 25 A, 14 V
Power relay F4 only
1 make contact (2 x pin 87)/
1 form A (2 x pin 87)
6 operations per minute (0.1 Hz)
Models with resistor or
diode in parallel to the
coil on request.
operations
2 x 100 A
> 2 x 10
Typ. 2 x 15 mV, 200 mV max.
2 x 25 A
2 x 40 A
Load limit curve 1
during transit time (changeover contact)
Load limit curve 2
no stationary arc (make contact)
12 V
Double make contact/
See load limit curve
> 10
5
AgNi0.15
Form U
1 A at 5 V
7
operations
2 x 15 A, 28 V
operations
2 x 100 A
> 1 x 10
^
= arc extinguishes
^
= safe shutdown,
2 x 15 A
2 x 15 A
24 V
5
(NO contact) (NO contact) (NO contact)
operations
40 A, 14 V
> 2 x 10
45/120A
30/40 A
40/60A
NC/NO
12 V
1 changeover contact/
1 form C
Typ. 15 mV, 200 mV max.
Typ. 20 mV, 250 mV max.
AgNi0.15
Models with resistor or
diode in parallel to the
coil on request.
5
Changeover contact/
operations
20 A, 28 V
> 1 x 10
45/120A
15/20 A
15/20A
Form C
NC/NO
24 V
Catalog 1308028
5
Issued 01-05
(NC contact)
operations
30 A, 28 V
operations
10 A, 28 V
> 1 x 10
> 5 x 10
45/120A
20/30 A
AgSnO
20/30A
NC/NO
24 V
3)
2
5
5

Related parts for V23134A1052C643