STMPE821QTR STMicroelectronics, STMPE821QTR Datasheet - Page 8

IC CTLR TOUCH KEY 8CH CAP 16-QFN

STMPE821QTR

Manufacturer Part Number
STMPE821QTR
Description
IC CTLR TOUCH KEY 8CH CAP 16-QFN
Manufacturer
STMicroelectronics
Type
Capacitiver
Datasheets

Specifications of STMPE821QTR

Number Of Inputs/keys
8 Key
Data Interface
I²C
Voltage - Supply
1.65 V ~ 1.95 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
16-QFN
Voltage Supply Source
Single Supply
Resolution
7 bit to 10 bit
Interface Type
I2C
Supply Voltage (max)
3.6 V
Supply Voltage (min)
2.7 V
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Number Of Channels
8
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Sampling Rate (per Second)
-
Resolution (bits)
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
497-8826-2

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
STMPE821QTR
Manufacturer:
STM
Quantity:
1 261
STMPE821 functional overview
1.4
8/50
Calibration algorithm
The STMPE821 maintains 2 parameters for each TOUCH channel: TVR and CALIBRATED
IMPEDANCE. CALIBRATED IMPEDANCE is an internal reference of which, if the currently
measured IMPEDANCE exceeds the CALIBRATED IMPEDANCE by a magnitude of TVR, it
is considered a TOUCH.
If the IMPEDANCE is more than the CALIBRATED IMPEDANCE, but the magnitude does
not exceed CALIBRATED IMPEDANCE by TVR, it is not considered a TOUCH. In this case,
2 scenarios are possible:
1. Environmental changes has caused the IMPEDANCE to increase
2. Finger is near the sensing pad, but not near enough
In case 1, the change in IMPEDANCE is expected to be small, as environmental changes
are normally gradual. A value "EVR" is maintained to specify the maximum IMPEDANCE
change that is still considered an environmental change.
Table 3.
‘IMP’ and ‘CALIBRATED IMP’ used in this table is not the direct register read-out.
IMP = 127 - impedance register read-out
CALIBRATED IMP = 127 - calibrated impedance register read out.
ETC WAIT register state a period of time of which, all TOUCH inputs must remain "NO
TOUCH" for the next calibration to be carried out.
CAL INTERVAL states the period of time between successive calibrations when there are
prolonged NO TOUCH condition.
IMP>CALIBRATED IMP + TVR
IMP<CALIBRATED IMP + TVR
IMP>CALIBRATED IMP + EVR
IMP<CALIBRATED IMP + TVR
IMP<CALIBRATED IMP + EVR
IMP>CALIBRATED IMP
IMP>CALIBRATED IMP
IMP<CALIBRATED IMP
Calibration action under different scenarios
Scenario
Doc ID 14478 Rev 5
TOUCH,
no calibration
NO TOUCH,
no calibration
NO TOUCH,
new CALIBRATED IMP = previous CALIBRATED
IMP + change in IMP
CALIBRATED IMP + change in IMP
NO TOUCH,
new CALIBRATED IMP = new IMP
Touch sensing and calibration action
STMPE821

Related parts for STMPE821QTR