66253-2 TE Connectivity, 66253-2 Datasheet - Page 3

MALE CONTACT ASSY. (STRIP)

66253-2

Manufacturer Part Number
66253-2
Description
MALE CONTACT ASSY. (STRIP)
Manufacturer
TE Connectivity
Series
Type XIIr
Datasheets

Specifications of 66253-2

Rohs Compliant
YES
Insulation Support
Yes
Termination Method To Wire/cable
Crimp
Wire/cable Type
Discrete Wire
Grade
Commercial
High Current
No
Termination End Plating
Gold (30)
Wire Range (mm [awg])
5.00-8.00² [10 - 8]
Used With
G Series Connectors, CPC Connectors, M Series Connectors
Contact Type
Pin
Contact Classification
Power
Contact Plating, Mating Area, Material
Gold (30)
Contact Base Material
Copper
Contact Size
Power Contact
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Accepts Wire Insulation Diameter, Range (mm [in])
4.83 – 5.59 [0.190 – 0.220]
Applies To
Wire/Cable
Test Current (a)
35.0
Packaging Method
Strip
3.6.
4.
4.1.
4.2.
4.3.
4.4.
Rev B
Product Qualification and Requalification Test Sequence
QUALITY ASSURANCE PROVISIONS
Qualification Testing
A.
B.
Requalification Testing
If changes significantly affecting form , fit or function are m ade to the product or m anufacturing process,
product assurance shall coordinate requalification testing, consisting of all or part of the original testing
sequence as determ ined by developm ent/product, quality and reliability engineering.
Acceptance
Acceptance is based on verification that the product m eets the requirem ents of Figure 1. Failures
attributed to equipm ent, test setup or operator deficiencies shall not disqualify the product. If product
failure occurs, corrective action shall be taken and specim ens resubm itted for qualification. Testing to
confirm corrective action is required before resubm ittal.
Quality Conform ance Inspection
The applicable AMP quality inspection plan shall specify the sam pling acceptable quality level to be
used. Dim ensional and functional requirem ents shall be in accordance with the applicable product
drawing and this specification.
NOTE
Specim en Selection
Specim ens shall be prepared in accordance with applicable Instruction Sheets and shall be
selected at random from current production. All test groups shall each consist of 3 specim ens.
Test Sequence
Qualification inspection shall be verified by testing specim ens as specified in Figure 2.
(a)
(b)
See paragraph 4.1.A.
Numbers indicate sequence in which tests are performed.
Initial exam ination of product
Tem perature rise vs current
Contact retention
Final exam ination of product
Test or Exam ination
Figure 2
Test Sequence (b)
Test Group (a)
1
1
2
3
1
3
2
2
108-10024-4
3 of 4

Related parts for 66253-2