66253-2 TE Connectivity, 66253-2 Datasheet - Page 2

MALE CONTACT ASSY. (STRIP)

66253-2

Manufacturer Part Number
66253-2
Description
MALE CONTACT ASSY. (STRIP)
Manufacturer
TE Connectivity
Series
Type XIIr
Datasheets

Specifications of 66253-2

Rohs Compliant
YES
Insulation Support
Yes
Termination Method To Wire/cable
Crimp
Wire/cable Type
Discrete Wire
Grade
Commercial
High Current
No
Termination End Plating
Gold (30)
Wire Range (mm [awg])
5.00-8.00² [10 - 8]
Used With
G Series Connectors, CPC Connectors, M Series Connectors
Contact Type
Pin
Contact Classification
Power
Contact Plating, Mating Area, Material
Gold (30)
Contact Base Material
Copper
Contact Size
Power Contact
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Accepts Wire Insulation Diameter, Range (mm [in])
4.83 – 5.59 [0.190 – 0.220]
Applies To
Wire/Cable
Test Current (a)
35.0
Packaging Method
Strip
3.
3.1.
3.2.
3.3.
3.4.
3.5.
Rev B
Initial exam ination of product.
Final exam ination of product.
Tem perature rise vs current.
Contact retention.
NOTE
REQUIREM ENTS
Design and Construction
Product shall be of the design, construction and physical dim ensions specified on the applicable product
drawing.
Materials
Materials used in the construction of this product shall be as specified on the applicable product
drawing.
Ratings
!
!
!
!
Perform ance and Test Description
Product is designed to m eet the electrical, m echanical and environm ental perform ance requirem ents
specified in Figure 1. Unless otherwise specified, all tests shall be perform ed at am bient environm ental
conditions per Test Specification 109-1.
Test Requirem ents and Procedures Sum m ary
Test Description
Voltage: 600 volts AC/DC
Current: 47.48 am peres (single circuit energized on 10 AW G wire)
Tem perature: -55 to 105°C
VDE 0627: XA/630/4KV/2 - Series I, VDE tested only
Shall meet visual requirements, show no physical damage, and meet requirements of additional
tests as specified in the Product Qualification and Requalification Test Sequence shown in Figure
2.
Meets requirem ents of product
drawing.
Meets visual requirem ents.
30 C m axim um tem perature rise at
specified current.
80.09 N [18 lb].
See Note.
MECHANICAL
ELECTRICAL
Requirem ent
Figure 1
EIA-364.
EIA-364.
Visual and dim ensional inspection
per product drawing.
Visual inspection.
EIA-364-70.
Measure tem perature rise vs
current.
See Figure 3.
IEC 60512-15-1.
Procedure
108-10024-4
2 of 4

Related parts for 66253-2