LTC2411-1CMS#TR Linear Technology, LTC2411-1CMS#TR Datasheet - Page 14

IC A/DCONV DIFF INPUT&REF 10MSOP

LTC2411-1CMS#TR

Manufacturer Part Number
LTC2411-1CMS#TR
Description
IC A/DCONV DIFF INPUT&REF 10MSOP
Manufacturer
Linear Technology
Datasheet

Specifications of LTC2411-1CMS#TR

Number Of Bits
24
Sampling Rate (per Second)
6.8
Data Interface
MICROWIRE™, Serial, SPI™
Number Of Converters
2
Power Dissipation (max)
1mW
Voltage Supply Source
Single Supply
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
10-TFSOP, 10-MSOP (0.118", 3.00mm Width)
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
LTC2411-1CMSTR
LTC24111CMSTR

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
LTC2411-1CMS#TRLTC2411-1CMS
Manufacturer:
LT
Quantity:
10 000
Company:
Part Number:
LTC2411-1CMS#TRLTC2411-1CMS
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Company:
Part Number:
LTC2411-1CMS#TRLTC2411-1CMS#PBF
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Company:
Part Number:
LTC2411-1CMS#TRPBF
Manufacturer:
LINEAR/凌特
Quantity:
20 000
APPLICATIO S I FOR ATIO
LTC2411/LTC2411-1
As long as the voltage on the IN
within the – 0.3V to (V
operating range, a conversion result is generated for any
differential input voltage V
+FS = 0.5 • V
+FS, the conversion result is clamped to the value corre-
sponding to the +FS + 1LSB. For differential input voltages
below –FS, the conversion result is clamped to the value
corresponding to –FS – 1LSB.
Frequency Rejection Selection (F
The LTC2411 internal oscillator provides better than 110dB
normal mode rejection at the line frequency and all its
harmonics for 50Hz 2% or 60Hz 2%. For 60Hz rejec-
tion, F
rejection the F
The selection of 50Hz or 60Hz rejection can also be made
by driving F
change during the sleep or data output states will not
disturb the converter operation. If the selection is made
during the conversion state, the result of the conversion in
progress may be outside specifications but the following
conversions will not be affected.
When a fundamental rejection frequency different from
50Hz or 60Hz is required or when the converter must be
synchronized with an outside source, the LTC2411 can
operate with an external conversion clock. The converter
automatically detects the presence of an external clock
signal at the F
frequency f
2560Hz (1Hz notch frequency) to be detected. The exter-
nal clock signal duty cycle is not significant as long as the
minimum and maximum specifications for the high and
low periods t
While operating with an external conversion clock of a
frequency f
normal mode rejection in a frequency range f
function of the input frequency deviation from f
is shown in Figure 4.
Whenever an external clock is not present at the F
converter automatically activates its internal oscillator and
14
4% and its harmonics. The normal mode rejection as a
O
should be connected to GND while for 50Hz
EOSC
EOSC
REF
O
HEO
O
O
to an appropriate logic level. A selection
pin and turns off the internal oscillator. The
. For differential input voltages greater than
, the LTC2411 provides better than 110dB
pin should be connected to V
of the external signal must be at least
and t
U
LEO
CC
U
are observed.
IN
+ 0.3V) absolute maximum
from –FS = –0.5 • V
+
and IN
O
W
) (LTC2411 Only)
pins is maintained
CC
EOSC
EOSC
U
.
O
pin, the
REF
/2560
/2560
to
enters the Internal Conversion Clock mode. The LTC2411
operation will not be disturbed if the change of conversion
clock source occurs during the sleep state or during the
data output state while the converter uses an external
serial clock. If the change occurs during the conversion
state, the result of the conversion in progress may be
outside specifications but the following conversions will
not be affected. If the change occurs during the data output
state and the converter is in the Internal SCK mode, the
serial clock duty cycle may be affected but the serial data
stream will remain valid.
Table 3 summarizes the duration of each state and the
achievable output data rate as a function of F
Simultaneous Frequency Rejection (LTC2411-1 Only)
The LTC2411-1 internal oscillator provides better than
87dB normal mode rejection over the range of 49Hz to
61.2Hz. For this simultaneous 50/60Hz rejection, F
be connected to GND. The performance of the LTC2411-1
is the same as the LTC2411 when driven by an external
conversion clock at F
SERIAL INTERFACE PINS
The LTC2411/LTC2411-1 transmit the conversion results
and receive the start of conversion command through a
synchronous 3-wire interface. During the conversion and
sleep states, this interface can be used to assess the
Figure 4. LTC2411 Normal Mode Rejection When
Using an External Oscillator of Frequency f
–100
–105
–110
–115
–120
–125
–130
–135
–140
–80
–85
–90
–95
DEVIATION FROM NOTCH FREQUENCY f
–12
DIFFERENTIAL INPUT SIGNAL FREQUENCY
–8
O
–4
pin.
0
4
EOSC
8
/2560(%)
2411 F04
12
EOSC
O
.
O
should

Related parts for LTC2411-1CMS#TR