2-964296-1 TE Connectivity, 2-964296-1 Datasheet - Page 6

FLACHSTECKER2,8X0,8

2-964296-1

Manufacturer Part Number
2-964296-1
Description
FLACHSTECKER2,8X0,8
Manufacturer
TE Connectivity
Series
Junior-Power-Timer (JPT), Multiple Contact Point (MCP), Sensorr
Datasheets

Specifications of 2-964296-1

Product Type
Contact
Mating Area Interface Dimensions (mm [in])
2.79 x 0.81 [.110 x .032]
Wire/cable Type
Regular Wire
Insulation Support
With
Wire Range (mm [awg])
1.00-2.50² [17-13]
Single Wire Sealing System
No
Tab Type
Symmetric Cantilever Steel Spring
Insulation Type
FLR (Thin Walled Cable)
Contact Type
Tab
Contact Base Material
CuFe2
Contact Plating, Mating Area, Material
Pre-Tin
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Accepts Wire Insulation Diameter, Range (mm [in])
2.21 – 3.00 [0.087 – 0.118]
Applies To
Wire/Cable
Packaging Method
Strip
Packaging Quantity
3,300

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
2-964296-1
Manufacturer:
TE/AMP
Quantity:
30 000
Housing Ass’y 6p Rec. & Tab Hybrid Jr. Power Timer / Multi Lock
Revisão “B”
4.5.12
4.5.13
4.5.14
4.5.15
4.5.16
4.5.17
4.5.18
4.5.19
ITEM
Connector to Connector
Connector Polarization
Disengagement Force
Disengagement Force
Un-Locked Connector
Feature Effectiveness
Isolation Resistance
Engagement Force
Locked Connector
Dielectric Strength
Terminal Position
Flammability
Assurance
TEST
CONNECTOR SYSTEM MECHANICAL TESTS
when tested according to GMW 3232 shall be
occur between cavities at any time during the
occur between the cavities and the outside of
TPA closing force with correct assembled
Damages do not have to occur that harm a
No dielectric breakdown or flash-over shall
No dielectric breakdown or flash-over shall
The burn rate of the material test samples
Electric continuity does not have to occur;
TPA closing force with one improperly
partially inserted terminal shall be greater
The closing force with one improperly or
a connector at any time during the test.
It does not have to allow assembly;
(with all the inserted terminals).
than 60 N for all terminal sizes.
12,5N minimum Hsg assy rec;
20N minimum Hsg assy tab.
17N minimum Hsg assy rec;
25N minimum Hsg assy tab.
Closed TPA locking force:
100 Mega-Ohms minimum.
less than 100 mm/min.
TPA Pre-Lock Force:
inserted terminal:
REQUIREMENTS
correct assembly.
100N maximum.
100N minimum.
30N maximum.
75N maximum.
terminals:
test;
terminal in housing with
terminal in housing with
in housing with a speed
samples during 3 to 23
500VDC / 15 seconds.
in all the ways, guiding
female, with terminals
them in incorrect way.
To extraction the TPA
rate of 50 10mm/min
connectors male and
together at a uniform
of 50±10mm/minute.
until fully seated and
flammability test per
1000Vac / 1 minute.
To try to mount the
To apply a force of
50±10mm/minute.
50±10mm/minute.
between 45-70%;
To extraction the
To extraction the
Mate connectors
hours ±5ºC, with
To condition the
relative humidity
PROCEDURES
Perform the
GMW 3232
a speed of
a speed of
locked.
150N.
108-37083
6 de 8

Related parts for 2-964296-1