2-964296-1 TE Connectivity, 2-964296-1 Datasheet - Page 5

FLACHSTECKER2,8X0,8

2-964296-1

Manufacturer Part Number
2-964296-1
Description
FLACHSTECKER2,8X0,8
Manufacturer
TE Connectivity
Series
Junior-Power-Timer (JPT), Multiple Contact Point (MCP), Sensorr
Datasheets

Specifications of 2-964296-1

Product Type
Contact
Mating Area Interface Dimensions (mm [in])
2.79 x 0.81 [.110 x .032]
Wire/cable Type
Regular Wire
Insulation Support
With
Wire Range (mm [awg])
1.00-2.50² [17-13]
Single Wire Sealing System
No
Tab Type
Symmetric Cantilever Steel Spring
Insulation Type
FLR (Thin Walled Cable)
Contact Type
Tab
Contact Base Material
CuFe2
Contact Plating, Mating Area, Material
Pre-Tin
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Accepts Wire Insulation Diameter, Range (mm [in])
2.21 – 3.00 [0.087 – 0.118]
Applies To
Wire/Cable
Packaging Method
Strip
Packaging Quantity
3,300

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
2-964296-1
Manufacturer:
TE/AMP
Quantity:
30 000
Housing Ass’y 6p Rec. & Tab Hybrid Jr. Power Timer / Multi Lock
Revisão “B”
4.5.10
4.5.11
ITEM
4.5.7
4.5.8
4.5.9
Terminal from Connector
Body Engagement Force
Temperature Humidity
Terminal to Connector
Extraction Force
Thermal Shock
Thermal Aging
Cycling
TEST
CONNECTOR ELECTRICAL TESTS
.
.
After 1008 hours / 85° C - Thermal Aging;
for service must function without breakage.
for service must function without breakage.
for service must function without breakage.
For terminal ≤2,8mm² Junior Power Timer:
For terminal ≤2,8mm² Junior Power Timer:
For terminal ≤2,8mm² Junior Power Timer:
With Sec. Lock Actuated Measurement;
elements required to separate connectors
elements required to separate connectors
elements required to separate connectors
continuity (resistance >7
For terminal with size 1,5mm² & 2,5mm²:
conditioned by being exposing to 95-
98% Relative Humidity at +40° C for 6
With Sec. Lock Actuated; and After
All mechanical assists and/or other
All mechanical assists and/or other
All mechanical assists and/or other
and After Temperature Humidity
There shall be no loss of electrical
For terminal ≤1,5mm² Multi Lock:
For terminal ≤1,5mm² Multi Lock:
For terminal ≤1,5mm² Multi Lock:
For terminal with size 0,5mm²:
For terminal with size 1,0mm²:
Item 4.5.1 / Item 4.5.3;
Item 4.5.1 / Item 4.5.3
Item 4.5.1 / Item 4.5.3
Primary Lock Only:
REQUIREMENTS
100N minimum.
15N maximum;
20N maximum;
30N maximum.
50N minimum;
90N minimum.
80N minimum;
70N minimum;
90N minimum.
Cycling:
this test;
hours:
> 1 s) during
To submit the samples 10
in housing with a speed of
To extraction the terminal
With the relative humidity
between 45% and 75%.
To insert the terminal in
housing with a speed of
cycles of 24 hours (T. -
To submit the samples
during 1008h/85ºC.
50±10mm/minute.
50±10mm/minute.
30 minute +85ºC
30 minute -40ºC
PROCEDURES
40° C to 85ºC);
100 cycles:
108-37083
5 de 8

Related parts for 2-964296-1