1-968855-1 TE Connectivity, 1-968855-1 Datasheet
1-968855-1
Specifications of 1-968855-1
Available stocks
Related parts for 1-968855-1
1-968855-1 Summary of contents
Page 1
... Tyco supplied com ponents. 1.2. Qualification W hen tests are perform ed on the subject product line, procedures specified in Figure 1 shall be used. All inspections shall be perform ed using the applicable inspection plan and product drawing. 2. APPLICABLE DOCUM ENTS The following docum ents form a part of this specification to the extent specified herein ...
Page 2
... W ire seal: Silicone rubber 3.3. Ratings ! Current: Refer to TE MCP 2 term inal system , part num ber 1-968857-1 sealed term inal 14 part num ber 1-968855-1 sealed term inal for electrical rating and heat rise characteristics ! Tem perature: -40 to 65°C !. Seal: Dust proof, SAEJ1455, 4.7.3, splash proof ...
Page 3
... See Note. Figure 1 (continued) 108-47001 Procedure Drop from a height [3.28 ft] onto a concrete floor on 3 corners and flat on latches. Two corners at bottom of cover (closed corners), 1 corner at seal area. Affixed to 750 m m [29.53 in] cable length, 40 wires m axim um , routed sym m etrically, dropped 8 tim es from 750 m m [29 ...
Page 4
... NOTE tests as specified in the Product Qualification and Requalification Test Sequence shown in Figure 2. Rev A Requirem ent Inserted contact m ust withstand a m inim um force [17.98 lbf] before disengagem ent from cavity, when pulled by the wire. All contact cavities to be tested. ENVIRONMENTAL See Note. ...
Page 5
... Resistance to vibrations Mechanical shock Durability Housing locking m echanism strength Contact retention strength Tem perature life Resistance to therm al shocks. Hum idity Dust bom bardm ent W ater tightness (a) See paragraph 4.1.A. NOTE (b) Numbers indicate sequence in which tests are performed. Rev A Test Group ( Test Sequence (b) ...
Page 6
... Acceptance Acceptance is based on verification that the product m eets the requirem ents of Figure 1. Failures attributed to equipm ent, test setup or operator deficiencies shall not disqualify the product. If product failure occurs, corrective action shall be taken and specim ens resubm itted for qualification. Testing to confirm corrective action is required before resubm ittal ...
Page 7
... Fuse, 10A Hi-Beam : A9 and A10 Fuse, 10A Lo-Beam : A7 and A8 Diode, 1A Neutral: D1 and D2 Diode, 1A Reverse: A1 and A2 1.0 am pere All fuse and diodes 10 am peres and less - wire peres - wire peres - wire Decal picture provided for illustration only. Spare fuses are not to be used in testing and NOTE unused contact cavities to be plugged with TE plugs part number 828922-1. Data shows time the main fuse contact reaches 80° ...
Page 8
... Linear slopes on log-log plots only. RMS G Level - 3.2 G's. Maximum G level limited the RMS level. Tolerance: ± from 10 to 2000 Hz. Figure 5 Vibration Profile 108-47001 Slope Between Breakpoints 0.0 -5.42 0.0 -9.20 -20.02 -100.12 ...