Specifications of K3HB-SSD 24VACVDC

Measuring Range
0 ~ 20mA, 0 ~ 10V
Display Style
Green, Red Characters, Black Background
Display Type
LCD
Display Face Size
3.78" L x 1.89" W (96.0 x 48.0mm)
Display Digits
5
Display Digits - Height
0.193" (4.90mm), 0.559" (14.20mm)
Backlight
Green, Red
Mounting Type
Panel Mount
Termination
Screw Terminals
Voltage - Supply
24VAC/DC
Power Consumption
7W
Svhc
No SVHC (15-Dec-2010)
External Depth
95mm
External Length / Height
48mm
Ip/nema Rating
IP20
Operating Temperature Max
55°C
Operating Temperature Min
-10°C
Supply Voltage
RoHS Compliant
Approval Bodies
CE, CRUus, UL
Current Consumption
50mA
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
High-speed, High-precision
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
K3HB-SSD24VACVDC
K3HBSSD24VACVDC
■ Input Compensation/Display
Forces the present value to 0. (Convenient for setting reference val-
ues or deducting tares for weight measurement.)
Shifts the current value measured with a forced zero to 0 again. It is
possible to measure two or more compounds separately and then,
by releasing the tare zero and forced-zero, measure the combined
total.
Compensates for mild fluctuations in input signals due to factors
such as sensor temperature drift, based on OK (PASS) data at mea-
surement. (This function can be used with sampling hold, peak hold,
or bottom hold.).
Changes the display value to 0 for input values less than the set
value. It is enabled in normal mode only. (This function can be used,
for example, to stop negative values being displayed or to eliminate
flickering and minor inconsistencies near 0.)
The display refresh period can be lengthened to reduce flickering
and thereby make the display easier to read.
Values can be displayed in either red or green. With comparative out-
put models, the display color can also be set to change according to
the status of comparative outputs (e.g., green to red or red to green).
Forced-zero
Tare Zero
Zero-trimming
Zero-limit
Display Refresh Period
Display Color Selection
Example) Setting: grn-r
Comparative set value H
Comparative set value L
Zero-limit
L
setting
Display
99.87
110.00
Red
P
100.05
Green
110.00
X V S
V S
X V H S
X V H S
X V H S
X V H S
Red
Input
H
110.01
110.00
The current display value can be selected from the present value, the
maximum value, and the minimum value.
It is possible to specify (i.e., restrict) the values that the smallest dis-
played digit can change by. For example, if the setting is 2, the small-
est digit will only take the values 0, 2, 4, 6, or 8 and if the setting is 5,
it will only take the values 0 or 5. If the setting is 10, it will only take
the value of 0.
Display Value Selection
Step Value
Panel Meter Series
X V H S
X V H S
K3HB
B-37