K3HB-XAD 24VAC/VDC Omron, K3HB-XAD 24VAC/VDC Datasheet

PROCESS INDICATR DC CURRNT INPUT

K3HB-XAD 24VAC/VDC

Manufacturer Part Number
K3HB-XAD 24VAC/VDC
Description
PROCESS INDICATR DC CURRNT INPUT
Manufacturer
Omron
Series
K3HBr
Type
Process Meterr
Datasheets

Specifications of K3HB-XAD 24VAC/VDC

Measuring Range
0 ~ 199.99mA
Display Style
Green, Red Characters, Black Background
Display Type
LCD
Display Face Size
3.78" L x 1.89" W (96.0 x 48.0mm)
Display Digits
5
Display Digits - Height
0.193" (4.90mm), 0.559" (14.20mm)
Backlight
Green, Red
Mounting Type
Panel Mount
Termination
Screw Terminals
Voltage - Supply
24VAC/DC
Analog / Digital
Digital
Control Method
ON/OFF
Voltage Rating
24 V
Mounting
Panel
Size
95 mm L x 96 mm W x 44.8 mm H
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
K3HB-XAD24VAC/VDC
K3HBXAD24VACVDC
A Process Indicator Ideal for Discriminating and
Displaying Measurements for Voltage/Current
Signals
• Easy recognition of judgement results using color display that can be
• Equipped with a position meter for monitoring operating status trends.
• External event input allows use in various measurement and discrimina-
• Series expanded to include DeviceNet models.
• Short body with depth of only 95 mm (from behind the front panel), or
• UL certification approval (Certification Mark License).
• CE Marking conformance by third party assessment body.
• Water-resistant enclosure conforms to NEMA 4X (equivalent to IP66).
• Capable of high-speed sampling at 50 times per second (20 ms)
• Easy-to-set two-point scaling allows conversion and display of any user-
Model Number Structure
■ Model Number Legend
Base Units and Optional Boards can be ordered individually or as sets.
Base Units
1. Input Sensor Code
5. Supply Voltage
Optional Board
Sensor Power Supply/Output Boards
Relay/Transistor Output Boards
Event Input Boards
Note: 1. CPA can be combined with relay outputs only.
Accessories (Sold Separately)
K32-DICN: Special Cable (for event inputs, with 8-pin connector)
K32-BCD: Special BCD Output Cable
K3HB-X@
K33-@
K34-@
K35-@
switched between red and green.
tion applications.
97 mm for DeviceNet models.
set values.
Process Indicator
K3HB-X
VD: DC voltage input
AD: DC current input
VA: AC voltage input
AA: AC current input
100-240 VAC: 100 to 240 VAC
24 VAC/VDC: 24 VAC/VDC
2. Only one of the following can be used by each Digital Indicator: RS-232C/RS-485 communications, a linear output, or DeviceNet communications.
Refer to Safety Precautions for All Digital Panel
Meters.
2
3
4
1
5
Base Units with Optional Boards
2. Sensor Power Supply/Output Type Code
3. Relay/Transistor Output Type Code
4. Event input Type Code
Rubber Packing
Note: Rubber packing is provided with the Controller.
K3HB-X@-@@@
K32-P1
None: None
CPA: Relay output (PASS: SPDT) + Sensor power supply
L1A: Linear current output (0 to 20 or 4 to 20 mA DC) + Sensor power supply
L2A: Linear voltage output (0 to 5, 1 to 5, or 0 to 10 VDC) + Sensor power supply
A: Sensor power supply (12 VDC +/−10%, 80 mA)
FLK1A: Communications (RS-232C) + Sensor power supply
FLK3A: Communications (RS-485) + Sensor power supply
None: None
C1: Relay contact (H/L: SPDT each)
C2: Relay contact (HH/H/LL/L: SPST-NO each)
T1: Transistor (NPN open collector: HH/H/PASS/L/LL)
T2: Transistor (PNP open collector: HH/H/PASS/L/LL)
BCD∗: BCD output + transistor output (NPN open collector: HH/H/PASS/L/
DRT: DeviceNet (See note 2.)
∗ A Special BCD Output Cable (sold separately) is required.
None: None
1: 5 inputs (M3 terminal blocks), NPN open collector
2: 8 inputs (10-pin MIL connector), NPN open collector
3: 5 inputs (M3 terminal blocks), PNP open collector
4: 8 inputs (10-pin MIL connector), PNP open collector
LL)
(12 VDC +/−10%, 80 mA) (See note 1.)
(12 VDC +/−10%, 80 mA) (See note 2.)
(12 VDC +/−10%, 80 mA) (See note 2.)
(12 VDC +/−10%, 80 mA) (See note 2.)
(12 VDC +/−10%, 80 mA) (See note 2.)
1 2 3 4
Model
5
CSM_K3HB-X_DS_E_6_1
1

K3HB-XAD 24VAC/VDC Summary of contents

Page 1

... Only one of the following can be used by each Digital Indicator: RS-232C/RS-485 communications, a linear output, or DeviceNet communications. Accessories (Sold Separately) K32-DICN: Special Cable (for event inputs, with 8-pin connector) K32-BCD: Special BCD Output Cable CSM_K3HB-X_DS_E_6_1 Base Units with Optional Boards K3HB-X@-@@@ Sensor Power Supply/Output Type Code None: None CPA: Relay output (PASS: SPDT) + Sensor power supply (12 VDC +/− ...

Page 2

... DC power supply models. The OMRON S8VS-series DC Power Supply Unit is recommend- ed. 2. PNP input types are also available. 3. For K3HB-series DeviceNet models, use only the DeviceNet Connector included with the product. The crimp terminals provided are for Thin Cables. Load: 500 Ω max, Resolution: Approx. 10,000, Output error: ±0.5% FS Load: 5 kΩ ...

Page 3

... Power Frequency Magnetic Immunity EN61000-4-8: 30 A/m (50 Hz) continuous time Voltage Dips and Interruptions Immunity EN61000-4-11: 0.5 cycle, 0°/180°, 100% (rated voltage sweeps of 5 min each and Z directions 2 2 (100 m/s for relay outputs) 3 times each in 3 axes, 6 directions K3HB-X 3 ...

Page 4

... MΩ − E6 COM 4. The K3HB-XVA@@ complies with UL standards when the applied input voltage is within the range 0 to 150 VAC. If the input voltage is higher than 150 VAC, install an external transformer or take other measures to drop the voltage to 150 VAC or lower. Measurement range Input impedance ± ...

Page 5

... Error detection Vertical parity and FCS Parity check Odd, even Note: For details on serial and DeviceNet communications, refer to the Digital Indicator K3HB Communications User's Manual (Cat.No. N129). BANK4 --- ON residual voltage max. OFF leakage current: 1.5 mA max. Load current max. ...

Page 6

... Supplied from DeviceNet communications connector Keys Indications Drive Transistor circuit output Micro- computer Drive Relay output X circuit Drive DeviceNet DeviceNet circuit circuit Communi- Drive cations Communications circuit driver COM V O DC-DC Converter (isolated) K3HB-X Drop line length Total drop line (max.) length (max 156 m 6 ...

Page 7

... Turns ON when the tare zero function is T-ZR executed. Turns OFF not executed or is cleared. Turns ON when the forced-zero function is Zero executed. Turns OFF not executed or is cleared. (Excluding the K3HB-H.) Turns ON/OFF when hold input turns Hold ON/OFF. MAX/MIN Key LEVEL Key Used to switch the Used to switch level ...

Page 8

... V Refer to the following User's Manual for application precautions and other information required when using the Digital Indicator: K3HB-S/-X/-V/-H Digital Indicator User's Manual (Cat. No. N128) The manual can be downloaded from the following site in PDF format: OMRON Industrial Web http://www.fa.omron.co.jp Continuous Data Output REQ ...

Page 9

... K3HB-X 9 ...

Page 10

... Always use a EN/IEC-compliant power supply with reinforced insulation or double insulation for the DeviceNet power supply. • The product must be used indoors for the above applicable standards to apply. • The K3HB-XVA@@ complies with UL standards when the applied input voltage is within the range 0 to 150 VAC. K3HB-X B ...

Page 11

... XG4M-1030 (OMRON) • Special Cable (Sold separately) K32-DICN (OMRON) (XG4M-1030 with 3 m cable) BCD Output Cable Model K32-BCD K3HB end 38 mm Cover: HDR-E50LPA5 (manufactured by Honda Tsushin Co., Ltd.) Connector: HDR-E50MAG1 (manufactured by Honda Tsushin Co., Ltd.) Note: The BCD Output Cable has a D-sub plug. Cover: 17JE-37H-1A (manufactured by DDK); Connector: equivalent to 17JE-23370-02 (D1) (manufactured by DDK) ...

Page 12

... Previous Average Value Comparison Slight changes can be removed from input signals to detect only extreme changes. Input value 2 Input value 1 Input value (inp.a2) (inp.a1) (Reverse scaling) K3HB-X Sampling hold value ON Peak-to-peak value (b2−a2) (b1−a1) b1 'b2 a1 'a2 ...

Page 13

... If interruption memory is ON, the maximum and minimum values after the last resetting will be displayed. • If interruption memory is OFF, the maximum and minimum values will be displayed after the power supply is turned ON (or after the reset input is performed). Input Red 110.01 H 110.00 K3HB-X 13 ...

Page 14

... PASS output terminal. Terminal cover (included) Character Size for Main Display (mm) PV display SV display 14.2 100 3.5 (112) 7.6 12 1.3 95 *DeviceNet models Terminal: M3, Terminal Cover: Accessory K3HB-X Hysteresis Hysteresis Time Startup compensation time set time Panel Cutout Dimensions 120 min. 4.9 75 min Mounting Recommended Panel Thickness ...

Page 15

... Insert the adapter into the grooves on the left and right sides of the rear case and push until it reaches the panel and is fixed in place. Adapter ■ LCD Field of Vision The K3HB is designed to have the best visibility at the angles shown in the following diagram. 10° 30° ■ Rubber Packing ...

Page 16

... Doing so may occasionally result in minor or moderate injury due to electric shock. Do not use the equipment for measurements within Measurement Categories III and IV for K3HB-X and II, III, and IV for K3HB-S, K3HB-V, and K3HB-H (according to IEC61010-1). Doing so may occasionally cause unexpected operation, resulting in minor or moderate injury, or damage to the equipment ...

Page 17

... Reception interference may occur if the product is used close to a radio, television, or wireless. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. Digital Indicator Digital Indicator K3HB-X 17 ...

Page 18

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...