H7CX-A4D DC12-24Q Omron, H7CX-A4D DC12-24Q Datasheet - Page 60

COUNTER DGTL 4DIGIT 12V SRW TERM

H7CX-A4D DC12-24Q

Manufacturer Part Number
H7CX-A4D DC12-24Q
Description
COUNTER DGTL 4DIGIT 12V SRW TERM
Manufacturer
Omron
Series
H7CXr
Type
Digital Panel Meterr

Specifications of H7CX-A4D DC12-24Q

Count Rate
30Hz or 5kHz Selectable
Number Of Digits/alpha
4
Input Type
Voltage, Switch Closure, Transistor Switch
Output Type
Switch Closure
Voltage - Supply
12 V ~ 24 V
Display Type
LCD Programmable Color
Equipment Type
Digital Panel Meter
Input
4.5 V to 30 V
Termination Style
Screw
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H7CX-A4D DC12-24
H7CXA4DDC1224
Z2739
■ Precautions for Correct Use
External Power Supply
The capacity of the external power supply is 100 mA at 12 V. When
using a 24 VAC/12 to 24 VDC power supply, reduce the load with the
power supply voltage, as shown in the following diagram (DC power
supplies only).
Power Supplies
• Turn the power ON and OFF using a relay with a rated capacity of
• Be sure that the capacity of the power supply is large enough,
Power Failure Backup
All data is stored in the EEPROM when there is a power failure. The
EEPROM can be overwritten more than 100,000 times. EEPROM is
overwritten when the power is turned OFF or when settings are
changed.
■ Conformance to EN/IEC
• Specifications call for basic insulation between the power supply
• Input and output terminals are connected to devices without
• Input and output terminals are connected to devices with basic
10 A minimum to prevent contact deterioration due to inrush current
caused by turning the power ON and OFF.
otherwise the H7CX may not start due to inrush current (reference
value: approx. 10 A, 1.5 ms at 26.4 VAC) that may flow for an
instant when the H7CX is turned ON.
and input terminals, between the power supply and output
terminals, and between the input and output terminals. (The H7CX-
A@D is not insulated between the power supply and input
terminals.)
exposed charged parts.
insulation that is suitable for the maximum operating voltage.
Standards
(DC voltage supply only)
100
20
10.8
Power supply voltage (VDC)
15
H7CX
60