H7CX-A4D DC12-24Q Omron, H7CX-A4D DC12-24Q Datasheet - Page 36

COUNTER DGTL 4DIGIT 12V SRW TERM

H7CX-A4D DC12-24Q

Manufacturer Part Number
H7CX-A4D DC12-24Q
Description
COUNTER DGTL 4DIGIT 12V SRW TERM
Manufacturer
Omron
Series
H7CXr
Type
Digital Panel Meterr

Specifications of H7CX-A4D DC12-24Q

Count Rate
30Hz or 5kHz Selectable
Number Of Digits/alpha
4
Input Type
Voltage, Switch Closure, Transistor Switch
Output Type
Switch Closure
Voltage - Supply
12 V ~ 24 V
Display Type
LCD Programmable Color
Equipment Type
Digital Panel Meter
Input
4.5 V to 30 V
Termination Style
Screw
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H7CX-A4D DC12-24
H7CXA4DDC1224
Z2739
■ Operation in Configuration Selection Mode
Select which H7CX configuration is used (i.e., 1-stage counter, 2-stage counter, total and preset counter, batch counter, dual counter, or tachom-
eter) in configuration selection mode. The H7CX is also equipped with a DIP switch monitor function, a convenient function that enables the settings
of the DIP switch pins to be confirmed using the front display.
Note: 1. When the mode is changed to configuration selection mode, the present value is reset, outputs turns OFF, and counting (measuring)
2. Setting changes made in configuration selection mode are enabled when the mode is changed to run mode. If the configuration is
stops.
changed, the set value (or set value 1 and set value 2), OUT1 set value or OUT2 set value are initialized.
(See note 2.)
Counting stopped
Counting possible
Power ON
1 s min.
+
1
(See note 1.)
Configuration
selection
DIP switch
monitor
OFF
ON
To change the mode to configuration selection mode, press
the
mode will not change if the
Select the configuration using the
models)
The H7CX is factory-set to the 1-stage counter configuration (2-stage
counter configuration with H7CX-AW@/-A4W@ models).
The configuration that can be selected depend on the model.
The status of the DIP switch pins (1 to 8) can be confirmed using the
Note: This display is possible only if DIP switch pin 1 (DIP switch
(1-stage counter) (2-stage counter)
Example
settings) is set to ON (i.e., enabled).
1
keys.
Key for 1 s min. with the
1
2
3
4
5
(Total and preset
counter)
6
1
7
key is pressed first.
8
key held down. The
1
keys. (
(Batch counter)
Indicates that DIP switch pin 8 is ON.
Indicates that DIP switch pin 7 is OFF.
Indicates that DIP switch pin 6 is ON.
Indicates that DIP switch pin 5 is OFF.
Indicates that DIP switch pin 4 is ON.
Indicates that DIP switch pin 3 is OFF.
Indicates that DIP switch pin 2 is ON.
Indicates that DIP switch pin 1 is ON.
key only for 6-digit
(Dual counter)
(Tachometer)
H7CX-A
1
36