E5CN-R2MT-500 AC100-240 Omron, E5CN-R2MT-500 AC100-240 Datasheet - Page 24

CONTROL TEMP DIGITAL HEAT/COOL

E5CN-R2MT-500 AC100-240

Manufacturer Part Number
E5CN-R2MT-500 AC100-240
Description
CONTROL TEMP DIGITAL HEAT/COOL
Manufacturer
Omron
Series
E5CN-Tr
Type
Temperature Controller, Digitalr

Specifications of E5CN-R2MT-500 AC100-240

Input Type
RTD, Thermocouple (Multiple)
Controller Type
On/Off or Proportional (PID)
Temperature Range
Selectable, Varies By Input Type
Output Type
Relay
Supply Voltage
100 ~ 240VAC
Size
48mm W x 48mm H (1/16 DIN)
Features
Terminal Cover
Display Type
4 Digit (2)
Operating Temperature Max
55°C
Operating Temperature Min
-10°C
Temperature Accuracy ±
0.5%
Output Voltage Max
240VAC
Output Voltage Min
5V
Controller Input
Thermocouple Or RTD
Thermocouple Type
J, K, T, E, L, U, N, R, S, B, W, PLII
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Communications
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
E5CN-R2MT-500-AC100240
E5CNR2MT500AC100240
Z2409
11.When executing self-tuning, turn ON power to the load (e.g.,
12.A switch or circuit breaker must be provided close to the product.
13.Always turn OFF the power supply before pulling out the interior of
14.Do not use paint thinner or similar chemical to clean with. Use
15.Design the system (e.g., control panel) considering the 2 seconds
16.The output may turn OFF when shifting to certain levels. Take this
17.The number of EEPROM write operations is limited. Therefore,
18.Always touch a grounded piece of metal before touching the
19.Do not remove the terminal block. Doing so may result in failure or
20.Control outputs (for driving SSR) that are voltage outputs are not
21.When replacing the body of the Temperature Controller, check the
22.Use suitable tools when taking the Temperature Controller apart
23.Before connecting an Output Unit, confirm the specifications and
24.Check the orientation of the connectors on the Conversion Cable
25.Do not place heavy object on the Conversion Cable, bend the
26.Do not connect or disconnect the Conversion Cable while
27.Make sure that the Conversion Cable's metal components are not
28.Do not touch the connectors on the Conversion Cable with wet
29.Before using infrared communications, correctly attach the
Precautions for Correct Use
Service Life
1. Use the product within the following temperature and humidity
2. The service life of electronic devices like Temperature Controllers
heater) at the same time as or before supplying power to the
product. If power is turned ON to the product before turning ON
power to the load, self-tuning will not be performed properly and
optimum control will not be achieved.
The switch or circuit breaker must be within easy reach of the
operator, and must be marked as a disconnecting means for this
unit.
the product, and never touch nor apply shock to the terminals or
electronic components. When inserting the interior of the product,
do not allow the electronic components to touch the case.
standard grade alcohol.
of delay that the product's output to be set after power ON.
into consideration when performing control.
use RAM write mode when frequently overwriting data during
communications or other operations.
Temperature Controller to discharge static electricity from your
body.
malfunction.
isolated from the internal circuits. When using a grounded
thermocouple, do not connect any of the control output terminals
to ground. (Doing so may result in an unwanted circuit path,
causing error in the measured temperature.)
condition of the terminals. If corroded terminals are used, contact
failure in the terminals may cause the temperature inside the
Temperature Controller to increase, possibly resulting in fire. If the
terminals are corroded, replace the case as well.
for disposal. Sharp parts inside the Temperature Controller may
cause injury.
thoroughly read relevant information in the datasheet and manual
for the Temperature Controller.
before connecting the Conversion Cable. Do not force a connector
if it does not connect smoothly. Using excessive force may
damage the connector.
cable past its natural bending radius, or pull on the cable with
undue force.
communications are in progress. Product faults or malfunction
may occur.
touching the external power terminals.
hands. Electrical shock may result.
enclosed Mounting Adapter to the cable for the Support Software.
When connecting the infrared port on the cable to the Support
Software into the Adapter, insert the connector to the specified
line. Communications may not be possible if the connector is not
connected properly.
ranges:
Temperature: −10 to 55°C (with no icing or condensation)
Humidity: 25% to 85%
If the product is installed inside a control board, the ambient
temperature must be kept to under 55°C, including the
temperature around the product.
is determined not only by the number of times the relay is switched
but also by the service life of internal electronic components.
Component service life is affected by the ambient temperature: the
higher the temperature, the shorter the service life and, the lower
http://www.ia.omron.com/
Safety Precautions for E5@N/E5@N-H
3. When two or more Temperature Controllers are mounted
Measurement Accuracy
1. When extending or connecting the thermocouple lead wire, be
2. When extending or connecting the lead wire of the platinum
3. Mount the product so that it is horizontally level.
4. If the measurement accuracy is low, check to see if input shift has
Waterproofing
The degree of protection is as shown below. Sections without any
specification on their degree of protection or those with IP@0 are not
waterproof.
Operating Precautions
1. It takes approximately two seconds for the outputs to turn ON from
2. When using self-tuning, turn ON power for the load (e.g., heater)
3. When starting operation after the Temperature Controller has
4. Avoid using the Controller in places near a radio, television set, or
Others
1. The disk that is included with the Conversion Cable is designed for
2. Do not connect or disconnect the Conversion Cable connector
3. After connecting the Conversion Cable to the computer, check the
4. Do not connect the Conversion Cable through a USB hub. Doing
5. Do not use an extension cable to extend the Conversion Cable
6. The E5AN-H/E5EN-H use the same port for communications
Front panel: IP66
Rear case: IP20, Terminal section: IP00
(E5CN-U: Front panel: IP50, rear case: IP20, terminals: IP00)
the temperature, the longer the service life. Therefore, the service
life can be extended by lowering the temperature of the
Temperature Controller.
horizontally close to each other or vertically next to one another,
the internal temperature will increase due to heat radiated by the
Temperature Controllers and the service life will decrease. In such
a case, use forced cooling by fans or other means of air ventilation
to cool down the Temperature Controllers. When providing forced
cooling, however, be careful not to cool down the terminals
sections alone to avoid measurement errors.
sure to use compensating wires that match the thermocouple
types.
resistance thermometer, be sure to use wires that have low
resistance and keep the resistance of the three lead wires the
same.
been set correctly.
after the power supply is turned ON. Due consideration must be
given to this time when incorporating Temperature Controllers in a
sequence circuit.
at the same time as or before supplying power to the Temperature
Controller. If power is turned ON for the Temperature Controller
before turning ON power for the load, self-tuning will not be
performed properly and optimum control will not be achieved.
warmed up, turn OFF the power and then turn it ON again at the
same time as turning ON power for the load. (Instead of turning the
Temperature Controller OFF and ON again, switching from STOP
mode to RUN mode can also be used.)
wireless installing. These devices can cause radio disturbances
which adversely affect the performance of the Controller.
a computer CD-ROM driver. Never attempt to play the disk in a
general-purpose audio player.
repeatedly over a short period of time. The computer may
malfunction.
COM port number before starting communications. The computer
requires time to recognize the cable connection. This delay does
not indicate failure.
so may damage the Conversion Cable.
length when connecting to the computer. Doing so may damage
the Conversion Cable.
through the infrared port and the Support Software port. Do not
attempt to use communications through the Support Software port
when the infrared port is being used.
(c)Copyright OMRON Corporation 2008 All Rights Reserved.