E53-COV04 Omron, E53-COV04 Datasheet - Page 41

no-image

E53-COV04

Manufacturer Part Number
E53-COV04
Description
E5CJ TERMINAL COVER
Manufacturer
Omron
Datasheet

Specifications of E53-COV04

Accessory Type
Terminal Cover
For Use With/related Products
E5CJ
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
E53COV04
Terminal Arrangement
E5CJ Standard Model
See note 2.
100 to 240 VAC, 50 or 60 Hz, 12 VA
or
24 VAC, 50 or 60 HZ, 10 VA
24 VDC 6 W
(Heater burnout alarm
and temperature alarm)
Alarm output 2
1 A (resistive load)
at 250 VAC
Alarm
output 1
Note
Event input 1 (EV1) Exter-
nally selects the set point.
open
short-circuit
2. Only the heater burnout alarm will be output from the alarm output 1 termi-
1. The event input terminals and voltage output and current output terminals
2. Only the heater burnout alarm will be output from the alarm output 1 termi-
3. A simple model with no alarm does not incorporate any event input or alarm
(ALM1)
nals if alarm mode switch 1 is set to 0. Only the temperature alarm will be
output if the heater burnout alarm value is set to 0.0 A.
are not insulated.
nals if alarm mode switch 1 is set to 0. Only the temperature alarm will be
output if the heater burnout alarm value is set to 0.0 A.
output. A simple model with an alarm function does not incorporate any
event input.
5
4
3
2
1
See note 1.
14
13
12
11
CT
+
Control output (OUT)
12 VDC
+
+
Use the E54-CT1 with a hole
diameter of 5.8 mm or E54-CT3 with a hole
diameter of 12 mm (both sold separately).
10
10
10
9
9
9
8
7
6
Voltage Output Unit
(20 mA max.)
Current Output Unit
4 to 20 mA DC
(with a load of 600
+
Relay Output Unit
3 A (resistive load)
at 250 VAC
A
B
B
max.)
Section 5-3
39