GU256X128D-3900B Noritake Company Inc, GU256X128D-3900B Datasheet - Page 61

no-image

GU256X128D-3900B

Manufacturer Part Number
GU256X128D-3900B
Description
MODULE VF GRAPHIC DISPLY 256X128
Manufacturer
Noritake Company Inc

Specifications of GU256X128D-3900B

Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
GU256X128D-3900B
Manufacturer:
PANASONIC
Quantity:
600 000
4.7.4.67
transfer)
4.7.4.68
Code:
Code:
Definable area: m1, m2 = 30h (General-purpose RAM):
Function:
Storage that would exceed the address range cannot be set.
For General-purpose RAM, data is transferred only into the specified address range.
For General-purpose FROM, data is transferred into the specified address range, and all other
memory locations in the same FROM area are set to FFh. Further, it is not possible to specify data
transfer that would exceed a general-purpose FROM area.
Operation is not guaranteed if source and destination areas overlap.
This command is valid in both User setup mode and Normal mode.
Definable area: m1 = 30h (General-purpose RAM):
Function:
Data read that would exceed the address range cannot be set.
This command is valid in both User setup mode and Normal mode.
The following data is transmitted from the RS-232 interface:
US ( e 19h sL sH sE m1 a1L a1H a1E m2 a2L a2H a2E
US ( e 28h sL sH sE m1 a1L a1H a1E
1Fh 28h 65h 19h sL sH sE m1 a1L a1H a1E m2 a2L a2H a2E
1Fh 28h 65h 28h sL sH sE m1 a1L a1H a1E
sL:
sH:
sE:
m1:
a1L: Destination address, lower byte
a1H: Destination address, upper byte
a1E: Destination address, extension byte
m2:
a2L: Source address, lower byte
a2H: Source address, upper byte
a2E: Source address, extension byte
sL:
sH:
sE:
m1:
a1L: Memory address, lower byte
a1H: Memory address, upper byte
a1E: Memory address, extension byte
Transfer data between general-purpose memory areas.
Send data stored in general-purpose memory.
(1) Header
(2) Identifier 1
(3) Identifier 2
(4) Data
Transmitted data
Transfer size, lower byte
Transfer size, upper byte
Transfer size, extension byte
Destination memory select
Source memory select
m1, m2 = 31h (General-purpose FROM):
Note: General-purpose FROM is in units of 001000h, with a total of 16 areas.
Data size, lower byte
Data size, upper byte
Data size, extension byte
Memory select
m1 = 31h (General-purpose FROM):
Note: General-purpose FROM is in units of 001000h, with a total of 16 areas.
000001h ≤ (sL + sH×100h + sE×10000h) ≤ 000400h
000000h ≤ (a1L + a1H×100h + a1E×10000h) ≤ 0003FFh
000000h ≤ (a2L + a2H×100h + a2E×10000h) ≤ 0003FFh
000001h ≤ (sL + sH×100h + sE×10000h) ≤ 001000h
000000h ≤ (a1L + a1H×100h + a1E×10000h) ≤ 00FFFFh
000000h ≤ (a2L + a2H×100h + a2E×10000h) ≤ 00FFFFh
000001h ≤ (sL + sH×100h + sE×10000h) ≤ 000400h
000000h ≤ (a1L + a1H×100h + a1E×10000h) ≤ 0003FFh
000001h ≤ (sL + sH×100h + sE×10000h) ≤ 001000h
000000h ≤ (a1L + a1H×100h + a1E×10000h) ≤ 00FFFFh
- 61 -
00h–FFh
GU-3900B series “General Function” Software Specification
Hex
28h
65h
28h
(General-purpose memory send)
Data length
s byte(s)
1 byte
1 byte
1 byte
(General-purpose
memory

Related parts for GU256X128D-3900B