GU256X128D-3900B Noritake Company Inc, GU256X128D-3900B Datasheet - Page 23

no-image

GU256X128D-3900B

Manufacturer Part Number
GU256X128D-3900B
Description
MODULE VF GRAPHIC DISPLY 256X128
Manufacturer
Noritake Company Inc

Specifications of GU256X128D-3900B

Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
GU256X128D-3900B
Manufacturer:
PANASONIC
Quantity:
600 000
4.7.3.10
4.7.3.11
RAM Macro define / delete
FROM Macro define / delete
(Only valid in User setup
mode)
Macro execution
Macro end condition
Memory SW setting
(Only valid in User setup
mode)
Memory SW data send
General-purpose memory
store
General-purpose memory
transfer
Command Name
Command Name
Macro setting commands
Other setting commands
1Fh,3Ah,pL,pH,
d1...dk
1Fh,28h,65h,12h,
a,pL,pH,t1,t2,
d(1)...d(p)
1Fh,5Eh,a,t1,t2
1Fh,28h,69h,20h,
a,b,c
Default: a=00h,
b=00h, c=00h or
Memory SW
setting.
1Fh,28h,65h,03h,
a,b
1Fh,28h,65h,03h,
a,b,c[1],d[1]
[...c[b],d[b]]
1Fh,28h,65h,04h,a
1Fh,28h,65h,04h,
a,b,c[1] [...c[b]]
1Fh,28h,65h,18h,
sL,sH,sE,m1,
a1L,a1H,a1E,
d[1]...d[s]
1Fh,28h,65h,19h,
sL,sH,sE,m1,
a1L,a1H,a1E,m2,
a2L,a2H,a2E
Hex Code
Hex Code
Define or delete RAM Macro or RAM Program Macro.
pL:
pH: RAM Macro data length, upper byte
d1...dk:
Define or delete FROM Macro or FROM Program Macro.
a:
pL:
pH: FROM Macro data length, upper byte
t1:
t2:
d(1)...d(P): FROM Macro data
Continuously execute Macro.
a:
a=00h:
a=01h–04h: FROM Macro 1–4
a=80h:
a=81h–84h: FROM Program Macro 1–4
t1:
t2:
Macro end condition set.
(Not applicable for Program Macro)
a: Macro end code Enable/Disable
b: Macro end code
c: Macro end Clear Screen setting
Set Memory SW.
Single setting:
a: Memory SW number
b: Setting value
Multiple setting (a=FFh):
b: Number of settings
c: Memory SW number
d: Setting value
Send the contents of Memory SW data.
Single read:
a: Memory SW number
Multiple read: (a=FFh)
b: No. of reads
c: Memory SW number
Store the supplied data into general-purpose memory.
sL:
sH: Data size, upper byte
sE: Data size, extension byte
m1: Memory select
a1L: Memory address, lower byte
a1H: Memory address, upper byte
a1E: Memory address, extension byte
d:
Transfer data between general-purpose memory areas.
sL:
sH: Transfer size, upper byte
sE: Transfer size, extension byte
m1: Destination memory select
a1L: Destination address, lower byte
a1H: Destination address, upper byte
a1E: Destination address, extension byte
m2: Source memory select
a2L: Source address, lower byte
a2H: Source address, upper byte
a2E: Source address, extension byte
- 23 -
RAM Macro data length, lower byte
FROM Macro definition number
FROM Macro data length, lower byte
Display time interval
Idle time for Macro repetition
Macro processing definition number
Display time interval
Idle time for Macro repetition
Data size, lower byte
Data to store
Transfer size, lower byte
GU-3900B series “General Function” Software Specification
RAM Macro data
RAM Macro
RAM Program Macro
Operation
Operation
Page
Page
p57
p57
p58
p59
p59
p60
p60
p61