AFCT-5760TP Avago Technologies US Inc., AFCT-5760TP Datasheet - Page 3

AFCT-5760TP

Manufacturer Part Number
AFCT-5760TP
Description
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of AFCT-5760TP

Optical Fiber Type
TX/RX
Data Transfer Rate
155Mbps
Optical Rise Time
2.5ns
Optical Fall Time
2.5ns
Operating Temperature Classification
Commercial
Peak Wavelength
1360nm
Package Type
SFP
Operating Supply Voltage (min)
3.1V
Operating Supply Voltage (typ)
3.3V
Operating Supply Voltage (max)
3.5V
Operating Temp Range
-10C to 85C
Mounting
Snap Fit To Panel
Pin Count
20
Lead Free Status / RoHS Status
Compliant
Transmitter Section
The transmitter section includes a 1310 nm Fabry-Perot
laser and a transmitter driver circuit. The driver circuit
maintains a constant optical power level provided that
the data pattern is valid for NRZ code. Connection to the
transmitter is provided via a LC optical connector.
The transmitter has full IEC 825 and CDRH Class 1 eye
safety.
TX_DISABLE
The transmitter output can be disabled by asserting pin
3, TX_DISABLE. A high signal asserts this function while
a low signal allows normal laser operation. The transmit-
ter output can also be disabled and monitored via the
2-wire serial interface. In the event of a transceiver fault,
such as the activation of the eye safety circuit, toggling
of the TX_DISABLE will reset the transmitter, as depicted
in Figure 2.
Figure 2. Typical Application Configuration
3
PROTOCOL
REFCLK
IC
Tx_FAULT
Rx_RATE
Rx_LOS
GPIO(X)
GPIO(X)
EWRAP
VREFR
GP14
RBC
TBC
TX[0:9]
TBC
EWRAP
RX[0:9]
RBC
Rx_RATE
3.3 V
REFCLK
VREFR
3.3 V
4.7 K to 10 KΩ
10 µF
SO+
SO–
SI+
SI–
100 Ω
0.1 µF
4.7 K to 10 KΩ
4.7 K to
10 KΩ
50 Ω
50 Ω
50 Ω
50 Ω
TX_FAULT
A laser fault or a low V
mitter fault signal, TX_FAULT, and disable the laser. This
signal is an open collector output (pull-up required on
the host board); A low signal indicates normal laser op-
eration and a high signal indicates a fault. The TX_FAULT
will be latched high when a laser fault occurs and is
cleared by toggling the TX_DISABLE input or power
cycling the transceiver. The TX_FAULT is not latched for
Low V
monitored via the two-wire serial interface (address A2,
byte 110, bit 2). By default, TX_FAULT is set to trigger on
hardware faults only.
4.7 K to
10 KΩ
1 µH
1 µH
CC
10 µF
. The transmitter fault condition can also be
4.7 K to
10 KΩ
Tx_DISABLE
Tx_FAULT
0.1 µF
MOD_DEF2
MOD_DEF1
MOD_DEF0
Rx_LOS
3.3 V
TD+
TD–
RD+
RD–
0.1
RX GND
TX GND
µF
V CC ,T
V CC ,R
CC
0.01 µF
0.01 µF
0.01 µF
0.01 µF
condition will activate the trans-
4.7 K to 10 KΩ
V CC ,R
V CC ,R
100 Ω
SFP MODULE
50 Ω
50 Ω
AMPLIFICATION
LASER DRIVER
QUANTIZATION
EEPROM
CIRCUITRY
& SAFETY
&