MT47H64M16HR-3 Micron Technology Inc, MT47H64M16HR-3 Datasheet - Page 115

no-image

MT47H64M16HR-3

Manufacturer Part Number
MT47H64M16HR-3
Description
Manufacturer
Micron Technology Inc
Datasheet

Specifications of MT47H64M16HR-3

Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MT47H64M16HR-3
Manufacturer:
MICREL
Quantity:
3 000
Part Number:
MT47H64M16HR-3
Manufacturer:
MICRON
Quantity:
20 000
Company:
Part Number:
MT47H64M16HR-3 :H
Quantity:
1 500
Part Number:
MT47H64M16HR-3 AAT:H
Manufacturer:
Micron Technology Inc
Quantity:
10 000
Part Number:
MT47H64M16HR-3 AAT:H TR
Manufacturer:
Micron Technology Inc
Quantity:
10 000
Part Number:
MT47H64M16HR-3 AIT:H
Manufacturer:
Micron Technology Inc
Quantity:
10 000
Company:
Part Number:
MT47H64M16HR-3 AIT:H
Quantity:
2 000
Part Number:
MT47H64M16HR-3 IT:G
Manufacturer:
Micron Technology Inc
Quantity:
10 000
Part Number:
MT47H64M16HR-3 IT:G TR
Manufacturer:
Micron Technology Inc
Quantity:
10 000
Part Number:
MT47H64M16HR-3 IT:H
Manufacturer:
MICRON
Quantity:
2 890
Part Number:
MT47H64M16HR-3:E
Manufacturer:
SIEMENS
Quantity:
347
Part Number:
MT47H64M16HR-3:E
Manufacturer:
MICRON
Quantity:
20 000
Part Number:
MT47H64M16HR-3:G
Manufacturer:
MICRON
Quantity:
11 200
Part Number:
MT47H64M16HR-3:G
Manufacturer:
MICRON
Quantity:
20 000
Figure 65: Data Input Timing
PRECHARGE
PDF: 09005aef821ae8bf
Rev. O 9/08 EN
Notes:
DQS#
Precharge can be initiated by either a manual PRECHARGE command or by an autopre-
charge in conjunction with either a READ or WRITE command. Precharge will deacti-
vate the open row in a particular bank or the open row in all banks. The PRECHARGE
operation is shown in the previous READ and WRITE operation sections.
During a manual PRECHARGE command, the A10 input determines whether one or all
banks are to be precharged. In the case where only one bank is to be precharged, bank
address inputs determine the bank to be precharged. When all banks are to be pre-
charged, the bank address inputs are treated as “Don’t Care.”
Once a bank has been precharged, it is in the idle state and must be activated prior to
any READ or WRITE commands being issued to that bank. When a single-bank PRE-
CHARGE command is issued,
mand is issued,
DQS
CK#
DM
DQ
CK
1.
2.
3. Subsequent rising DQS signals must align to the clock within
4. WRITE command issued at T0.
5. For x16, LDQS controls the lower byte and UDQS controls the upper byte.
6. WRITE command with WL = 2 (CL = 3, AL = 0) issued at T0.
t
t
DSH (MIN) generally occurs during
DSS (MIN) generally occurs during
T0
WL - t DQSS (NOM)
t
RPA timing applies, regardless of the number of banks opened.
T1
T1n
t WPRE
115
t
T2
DI
RP timing applies. When the PRECHARGE (ALL) com-
t DSH 1
T2n
t DQSL
t DSS 2
t
t
DQSS (MAX).
DQSS (MIN).
Micron Technology, Inc. reserves the right to change products or specifications without notice.
Transitioning Data
T3
3
t DQSH
t DSH 1
T3n
1Gb: x4, x8, x16 DDR2 SDRAM
t WPST
t DSS 2
T4
Don’t Care
© 2004 Micron Technology, Inc. All rights reserved.
t
DQSS.
PRECHARGE

Related parts for MT47H64M16HR-3