Specifications of MC33912G5AC

Turn Off Delay Time
10us
Number Of Drivers
4
Operating Temperature (min)
-40C
Operating Temperature (max)
125C
Operating Temperature Classification
Automotive
Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MC33912G5AC
Manufacturer:
FREESCALE
Quantity:
32 440
Part Number:
MC33912G5AC
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MC33912G5AC
Manufacturer:
FREESCALE
Quantity:
32 440
Part Number:
MC33912G5AC
Manufacturer:
FREESCALE
Quantity:
20 000
Part Number:
MC33912G5ACR2
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Int
(Run), Stop, and Sleep (Low Power). In Normal mode, the
device is active and is operating under normal application
conditions. The Stop and Sleep modes are low-power modes
with wake-up capabilities.
with V
voltage regulator is turned off (V
interrupt. Wake-up from Sleep mode is done by a reset and
the voltage regulator is turned back on.
MOD1:2 bits in the Mode Control Register (MCR).
different operating modes.
operating modes.
RESET MODE
mode, the RST pin is low for 1ms (typical value). After this
delay, it enters the Normal Request mode and the RST pin is
driven high.
low, watchdog trigger fail, after wake-up from Sleep mode,
Normal Request mode timeout occurs).
NORMAL REQUEST MODE
device after the Reset mode, or after a wake-up from Stop
mode.
RESET pin is High, and the LIN is operating in RX Only
mode.
an internal timer is started for 150 ms (typical value). During
these 150 ms, the MCU must configure the Timing Control
Register (TIMCR) and the Mode Control Register (MCR) with
MOD2 and MOD1 bits set = 0, to enter the Normal mode. If
within the 150ms timeout, the MCU does not command the
33912 to Normal mode, it will enter in Reset mode. If the
WDCONF pin is grounded in order to disable the watchdog
function, it goes directly in Normal mode after the Reset
mode. If the WDCONF pin is open, the 33912 stays typically
for 150 ms in Normal Request before entering in Normal
mode.
72
33912
FUNCTIONAL DEVICE OPERATIONS
OPERATIONAL MODES
The 33912 offers three main operating modes: Normal
In Stop mode, the voltage regulator still supplies the MCU
Wake-up from Stop mode is initiated by a wake-up
The selection of the different modes is controlled by the
Figure 38
The 33912 enters the Reset mode after a power up. In this
The Reset mode is entered if a reset condition occurs (V
This is a temporary mode automatically accessed by the
In Normal Request mode, the VDD regulator is ON, the
As soon as the device enters in the Normal Request mode
roduction
DD
(limited current capability), while in Sleep mode the
describes how transitions are done between the
Table 37
DD
= 0 V).
gives an overview of the
FUNCTIONAL DEVICE OPERATIONS
OPERATIONAL MODES
DD
NORMAL MODE
controlled by the SPI interface and the PWMIN pin.
capability.
pin and the Ground, the window watchdog function will be
enabled.
or have its voltage routed through the analog-multiplexer.
the LIN protocol specification 2.0. The LIN bus can transmit
and receive information.
PWM capability according to the SPI configuration.
over/under-voltage, thermal shutdown, or thermal shutdown
prewarning on the main regulator.
SLEEP MODE
mode, the device enters into Sleep mode by sending one SPI
command through the Mode Control Register (MCR). All
blocks are in their lowest power consumption condition. Only
some wake-up sources (wake-up inputs with or without cyclic
sense, forced wake-up and LIN receiver) are active. The
5.0 V regulator is OFF. The internal low-power oscillator may
be active if the IC is configured for cyclic-sense. In this
condition, one of the high side switches is turned on
periodically and the wake-up inputs are sampled.
device goes in Reset mode except that the SPI will report the
wake-up source and the BATFAIL flag is not set.
STOP MODE
case the 5.0 V regulator is ON with limited current drive
capability. The application MCU is always supplied while the
33912 is operating in Stop mode.
SPI command. When the application is in this mode, it can
wake-up from the 33912 side (for example: cyclic sense,
force wake-up, LIN bus, wake inputs) or the MCU side (CS,
RST pins). Wake-up from Stop mode will transition the 33912
to Normal Request mode and generates an interrupt except
if the wake-up event is a low to high transition on the CS pin
or comes from the RST pin.
In Normal mode, all 33912 functions are active and can be
The VDD regulator is ON and delivers its full current
If an external resistor is connected between the WDCONF
The wake-up inputs (L1-L4) can be read as digital inputs
The LIN interface has slew rate and timing compatible with
The high side and low side switches are active and have
The interrupts are generated to report failures for V
The Sleep mode is a low power mode. From Normal
Wake-up from Sleep mode is similar to a power-up. The
The Stop mode is the second low power mode, but in this
The device can enter into Stop mode only by sending the
Analog Integrated Circuit Device Data
Freescale Semiconductor