SC16C2550BIBS-S NXP Semiconductors, SC16C2550BIBS-S Datasheet - Page 21

no-image

SC16C2550BIBS-S

Manufacturer Part Number
SC16C2550BIBS-S
Description
Manufacturer
NXP Semiconductors
Datasheet

Specifications of SC16C2550BIBS-S

Transmit Fifo
16Byte
Receive Fifo
16Byte
Transmitter And Receiver Fifo Counter
Yes
Data Rate
5Mbps
Operating Supply Voltage (max)
5.5V
Mounting
Surface Mount
Pin Count
32
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Operating Temperature Classification
Industrial
Number Of Channels
2
Lead Free Status / RoHS Status
Compliant
NXP Semiconductors
SC16C2550B_5
Product data sheet
7.6 Modem Control Register (MCR)
Table 16.
Table 17.
This register controls the interface with the modem or a peripheral device.
Table 18.
LCR[2]
0
1
1
LCR[1]
0
0
1
1
Bit
7:5
4
3
2
1
0
Symbol
MCR[7:5]
MCR[4]
MCR[3]
MCR[2]
MCR[1]
MCR[0]
LCR[2] stop bit length
LCR[1:0] word length
Modem Control Register bits description
Word length (bits)
5, 6, 7, 8
5
6, 7, 8
LCR[0]
0
1
0
1
5 V, 3.3 V and 2.5 V dual UART, 5 Mbit/s (max.), with 16-byte FIFOs
Description
reserved; set to ‘0’
Loopback. Enable the local Loopback mode (diagnostics). In this mode the
transmitter output (TX) and the receiver input (RX), CTS, DSR, CD and RI
are disconnected from the SC16C2550B I/O pins. Internally the modem
data and control pins are connected into a loopback data configuration
(see
fully operational. The Modem Control Interrupts are also operational, but
the interrupts’ sources are switched to the lower four bits of the Modem
Control. Interrupts continue to be controlled by the IER register.
OP2/INT enable
(OP1). OP1A/OP1B are not available as an external signal in the
SC16C2550B. This bit is instead used in the Loopback mode only. In the
Loopback mode, this bit is used to write the state of the modem RI
interface signal.
RTS
DTR
Rev. 05 — 12 January 2009
logic 0 = disable Loopback mode (normal default condition)
logic 1 = enable local Loopback mode (diagnostics)
logic 0 = forces INT (A, B) outputs to the 3-state mode and sets OP2 to a
logic 1 (normal default condition)
logic 1 = forces the INT (A, B outputs to the active mode and sets OP2 to
a logic 0
logic 0 = force RTS output to a logic 1 (normal default condition)
logic 1 = force RTS output to a logic 0
logic 0 = force DTR output to a logic 1 (normal default condition)
logic 1 = force DTR output to a logic 0
Word length (bits)
5
6
7
8
Figure
7). In this mode, the receiver and transmitter interrupts remain
Stop bit length (bit times)
1
1
2
1
2
SC16C2550B