Page 1
... CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures. | 1-888-INTERSIL or 888-468-3774 Intersil (and design registered trademark of Intersil Americas Inc. Copyright Intersil Americas Inc. 2001-2006. All Rights Reserved. RSLIC18™ trademark of Intersil Americas Inc. All other trademarks mentioned are the property of their respective owners. HC55185 FN4831.14 ...
Page 2
... HC55185BIMZ* (Note) HC55185 BIMZ HC55185CIM* HC55185 CIM HC55185CIMZ* (Note) HC55185 CIMZ HC55185DIM* HC55185 DIM HC55185DIMZ* (Note) HC55185 DIMZ HC55185ECM* HC55185 ECM HC55185ECMZ* (Note) HC55185 ECMZ HC55185ECR* HC55185 ECR HC55185ECRZ* (Note) HC55185 ECRZ HC55185FCM* HC55185 FCM HC55185FCMZ* (Note) HC55185 FCMZ HC55185FCR* HC55185 FCR ...
Page 3
Pinouts HC55185 (28 LD PLCC) TOP VIEW SW+ 6 SW- 7 SWC HC55185 27 26 RTD 25 24 CDC 23 ...
Page 4
Absolute Maximum Ratings T A Maximum Supply Voltages ...
Page 5
Electrical Specifications Unless Otherwise Specified, T (C) grade, V All AC parameters are specified at 600Ω 2-wire terminating impedance over the frequency band of 300Hz to 3.4kHz. Protection resistors = 0Ω. (Continued) PARAMETER 2-Wire Longitudinal Balance (Notes 5, 6) 4-Wire ...
Page 6
Electrical Specifications Unless Otherwise Specified, T (C) grade, V All AC parameters are specified at 600Ω 2-wire terminating impedance over the frequency band of 300Hz to 3.4kHz. Protection resistors = 0Ω. (Continued) PARAMETER Input High Current LOGIC OUTPUTS (DET, ALM) ...
Page 7
... These can be used for CFB since it is internally limited to approximately ±3V. The CDC HC55185CIM capacitor may be either polarized or non polarized. HC55185DIM HC55185ECM Parametric Improvements The most significant parametric improvement of the HC55185 is reduction in Idle Channel Noise. This improvement was accomplished by redistributing gains in the impedance matching loop ...
Page 8
Functional Improvements In addition to parametric improvements, internal circuit changes and application circuit changes have been made to improve the overall device functionality. Off Hook Interface The transient behavior of the device in response to mode changes has been significantly ...
Page 9
Design Equations Loop Supervision Thresholds SWITCH HOOK DETECT The switch hook detect threshold is set by a single external resistor Equation 3 is used to calculate the value ⁄ R 600 ...
Page 10
Low Power Standby Overview The low power standby mode (LPS, 000) should be used during idle line conditions. The device is designed to operate from the high battery during this mode. Most of the internal circuitry is powered down, resulting ...
Page 11
Forward Active Overview The forward active mode (FA, 001) is the primary AC transmission mode of the device. On hook transmission, DC loop feed and voice transmission are supported during forward active. Loop supervision is provided by either the switch ...
Page 12
When R is exceeded, the device will transition from KNEE constant current feed to constant voltage, resistive feed. The line segment I represents the resistive feed portion of the B load characteristic ----------------------- - ...
Page 13
Since the current relationships are different for constant current versus constant voltage, the region of device operation is critical to valid power dissipation calculations. Reverse Active Overview The reverse active mode (RA, 011) provides the same functionality as the forward ...
Page 14
When operating from a battery of -100V, each amplifier, Tip and Ring, will swing a maximum of 95V maximum signal swing at VRS to achieve full scale ringing is approximately 2.4V . The low signal levels are compatible P-P with ...
Page 15
AC Verification The entire AC loop of the device is active during the forward loop back mode. Therefore a 4-wire to 4-wire level test capability is provided. Depending on the transhybrid balance implementation, test coverage is provided by a one ...
Page 16
High Voltage Decoupling The 100V rating of the device will require a capacitor of higher voltage rating for decoupling. Suggested decoupling values for all device pins are 0.1μF. Standard surface mount ceramic capacitors are rated at 100V. For applications driven ...
Page 17
... SW VFB R RTD RT SWC BSEL ILIM CDC POL F2 POL DET ALM AGND BGND FIGURE 15. HC55185 BASIC APPLICATION CIRCUIT 17 HC55185 TABLE 4. BASIC APPLICATION CIRCUIT COMPONENT U1 - Ringing SLIC PS1 C PS2 Standard applications will use ≥ 49Ω per side. Protection resistor values are application dependent and will be determined by protection requirements ...
Page 18
Pin Descriptions PLCC QFN SYMBOL 1 29 TIP TIP power amplifier output BGND Battery Ground - To be connected to zero potential. All loop current and longitudinal current flow from this ground. Internally separate from AGND but it ...
Page 19
... The pin #1 identifier may be either a mold or mark feature. improved electrical and thermal performance. Pattern Design efforts, see Intersil Technical Brief TB389. when Anvil singulation method is used and not present for saw singulation. package, a maximum 0.15mm pull back (L1) maybe present. L minus equal to or greater than 0 ...
Page 20
... Accordingly, the reader is cautioned to verify that data sheets are current before placing orders. Information furnished by Intersil is believed to be accurate and reliable. However, no responsibility is assumed by Intersil or its subsidiaries for its use; nor for any infringements of patents or other rights of third parties which may result from its use ...