SI2434-C-GT Silicon Laboratories Inc, SI2434-C-GT Datasheet - Page 34

no-image

SI2434-C-GT

Manufacturer Part Number
SI2434-C-GT
Description
Manufacturer
Silicon Laboratories Inc
Datasheet

Specifications of SI2434-C-GT

Main Category
Chipset
Data Rate
32.8125Kbps
Operating Supply Voltage (typ)
3.3V
Operating Supply Voltage (min)
3V
Operating Supply Voltage (max)
3.6V
Operating Temp Range
-40C to 85C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Lead Free Status / RoHS Status
Supplier Unconfirmed
Si2457/34/15/04
34
Notes:
Command
1. When in autobaud mode, \B0, \B1, and \P1 will not be detected automatically. The combination of \B2 and \P3 will be
2. The autobaud feature does not detect this rate.
\T10
\T11
\T12
\T13
\T14
\T15
\T16
\T17
\Q3
\Q4
\Tn
\T0
\T1
\T2
\T3
\T4
\T5
\T6
\T7
\T8
\T9
\U
detected. This is compatible with seven data bits, no parity, two stop bits. Seven data bits, no parity, one stop bit may be
forced by sending AT\T17\B1.
Table 13. Extended AT\ Command Set (Command Defaults in Bold) (Continued)
Use RTS/CTS
Use XON/XOFF flow control for modem-to-DTE interface. Does not enable modem-to-modem flow
control.
DTE rate—Change DTE rate. When the Si2457/34/15/04 is configured in autobaud mode (default),
\T0 through \T15 will lock the new baud rate and disable autobaud. On the 24-pin version, the ISO-
modem® is not in autobaud mode (pin 18 low on powerup), the result code “OK” is sent at the old
DTE rate. Subsequent commands must be sent at the new rate.
300 bps
600 bps
1200 bps
2400 bps
4800 bps
7200 bps
9600 bps
12.0 kbps
14.4 kbps
19.2 kbps
38.4 kbps
57.6 kbps
115.2 kbps
230.4 kbps
245.760 kbps
307.200 kbps
Autobaud on
Autobaud off; lock at current baud rate.
Serial mode—causes a low pulse (25 ms) on RI and DCD. INT to be the inverse of ESC. RTS to be
inverse of CTS.
Parallel mode—causes a low pulse (25 ms) on INT.
This command terminates with a RESET.
2
2
Rev. 1.1
Action

Related parts for SI2434-C-GT