SAB82525HV22XP Infineon Technologies, SAB82525HV22XP Datasheet - Page 94

no-image

SAB82525HV22XP

Manufacturer Part Number
SAB82525HV22XP
Description
Manufacturer
Infineon Technologies
Datasheet

Specifications of SAB82525HV22XP

Operating Supply Voltage (typ)
5V
Operating Supply Voltage (min)
4.75V
Operating Supply Voltage (max)
5.25V
Operating Temp Range
0C to 70C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
44
Lead Free Status / RoHS Status
Compliant
Receive Address Byte High Register 2 (WRITE)
RAH2
RAH2 … Value of second individual programmable high address byte.
MCS … Module Count Select; valid in auto-mode only.
Note:
Receive Address Byte High Register 1 (WRITE)
RAH1
In operating modes that provide high byte address recognition, the high byte of the received
address is compared with the individual programmable values in RAH1, or RAH2.
RAH1 … Value of the first individual high address byte
CRI … Command/Response Interpretation (auto-mode and non-auto mode only)
The setting of the CRI bit affects the meaning of the C/R bit in RSTA as follows:
C/R meaning
Commands received
Responses received
Important: If the 1 byte address field is selected in auto-mode, RAH1 must be set to 00
Semiconductor Group
The MCS bit adjusts the control field format according to the HDLC (ISDN/LAPD).
0 … basic operation (modulo 8)
1 … extended operation (modulo 128)
When modulo 128 is selected, in auto-mode the "RHCR" register contains compressed
information of the extended control field (see RHCR, register description). RAH1, RAH2
registers are used in auto and non-auto operating modes when a 2-byte address field
has been selected (MODE.ADM = 1) and in the transparent mode 0.
RAH2 has to be initialized.
CRI = 1
70
7
0
1
C/R value
CRI = 0
RAH2
RAH1
1
0
94
MCS
CRI
1
0
0
0
0
SAB 82525
SAB 82526
SAF 82525
SAF 82526
(27/67)
(26/66)
H .