SAB82525NV22XT Infineon Technologies, SAB82525NV22XT Datasheet - Page 80

no-image

SAB82525NV22XT

Manufacturer Part Number
SAB82525NV22XT
Description
Manufacturer
Infineon Technologies
Datasheet

Specifications of SAB82525NV22XT

Operating Supply Voltage (typ)
5V
Operating Supply Voltage (min)
4.75V
Operating Supply Voltage (max)
5.25V
Operating Temp Range
0C to 70C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
44
Lead Free Status / RoHS Status
Compliant
8.2 Register Definitions
Receive FIFO (Read) RFIFO (00. . .1F/40. . .5F)
Up to 32 bytes of receive data can be read from the RFIFO following an RPF or an RME
interrupt.
RPF Interrupt: Exactly 32 bytes to be read.
RME Interrupt: Number of bytes to be determined by reading the RBCL, RBCH registers.
If the RFIFO contains 32 bytes, the HSCX autonomously requests a block data transfer by
DMA activating the DRQR line as long as the start of the 32nd read cycle. This forces the DMA
controller to continuously perform bus cycles till 32 bytes are transferred from the HSCX to the
system memory, (level triggered, demand transfer mode of DMA controller).
If the RFIFO contains less than 32 bytes (one short frame or the last of a long frame) the HSCX
requests a block data transfer depending on the contents of the RFIFO according to the
following table:
Additionally an RME interrupt is issued after the last byte has been transferred.
As a result, the DMA controller may transfer more bytes as actually valid in the current received
frame. The valid byte count must therefore be determined by reading the RBCH, RBCL
registers following the RME interrupt.
RFIFO
Contents
(Bytes)
1, 2, 3
4 - 7
8 - 15
16 - 32
Semiconductor Group
Interrupt Controlled Data Transfer (Interrupt Mode)
selected if DMA bit in XBCH is reset.
DMA Controlled Data Transfer (DMA Mode)
selected if DMA bit in XBCH
DMA
Request
(Bytes)
4
8
16
32
80
SAB 82525
SAB 82526
SAF 82525
SAF 82526