TLE6266G Infineon Technologies, TLE6266G Datasheet - Page 8

no-image

TLE6266G

Manufacturer Part Number
TLE6266G
Description
Network Controller & Processor ICs BODY SYSTEM ICS
Manufacturer
Infineon Technologies
Datasheet

Specifications of TLE6266G

Number Of Transceivers
1
Operating Supply Voltage (max)
5.5V
Operating Supply Voltage (typ)
5V
Package Type
DSO
Operating Temperature (max)
150C
Operating Temperature (min)
-40C
Operating Temperature Classification
Automotive
Mounting
Surface Mount
Pin Count
28
Product
Controller Area Network (CAN)
Data Rate
125 KBd
Supply Voltage (max)
5.5 V
Supply Voltage (min)
4.8 V
Supply Current (max)
200 mA
Maximum Operating Temperature
+ 150 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Package / Case
DSO
Lead Free Status / RoHS Status
Not Compliant
Other names
TLE6266GNT

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TLE6266G
Manufacturer:
INFINEON
Quantity:
6 443
Part Number:
TLE6266G
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
6
The TLE 6266 G is a monolithic IC, which incorporates a failure tolerant low speed CAN-
transceiver for differential mode data transmission, a low dropout voltage regulator for
internal and external 5V supply as well as a SPI interface to control and monitor the IC.
Further there are three high side switches, two low side switches, a window watchdog
circuit and a reset circuit integrated. Figure 2 shows the block diagram of the TLE 6266.
6.1
The TLE 6266 offers four different operation modes (see Figure 3), that are controlled
via the SPI input bits 9,10 (mode bits M0,M1) as shown in Table 1: the normal operation
mode, the receive-only mode, the V
mode.
The cyclic wake mode itself is subdivided into two modes: the cyclic HS OFF and the
cyclic HS ON mode. Cyclic wake and V
that do not require communication on the CAN-Bus but offer a low power mode. The
lowest current consumption is achieved in the cyclic wake HS OFF mode.
Table 1
Normal operation
Cyclic Wake
RxD only
V
Normal Operation Mode
The normal operation mode is designed to receive and transmit data messages as well
as to supply the ECU and control loads via HS- and LS- switches. RTL is switched to
V
RxD-only Mode
In the receive-only mode the receiver stage is activated and the transmitter stage is
deactivated. This means that data at the TxD input is not transmitted to the CAN bus but
receiving of data is still possible. The CANL line is pulled-up to V
and CANH is pulled to GND via RTH. Furthermore, it is possible to bypass the signal at
TxD to the RxD output during this mode.This mode is useful in combination to a
dedicated network-management software that allows separate diagnosis for all nodes
(see Chapter 6.2). Table 3 gives an overview about the available functions in this mode.
Version 2.21
bat
CC
, RTH to GND. Table 3 gives an overview about the available functions in this mode.
stand-by
Circuit Description
Operation Modes
Operation modes bit settings
Mode Bit M1
(SPI Bit 10)
1
1
0
0
bat
Mode Bit M0
(SPI Bit 9)
1
0
1
0
bat
stand-by mode and the cyclic wake operation
stand-by mode are both designed for periods
8
Datasheet TLE 6266 G
CC
via the RTL output
July 29th, 2005