Specifications of TLE6262G

Number Of Transceivers
1
Power Down Mode
Sleep/Standby
Operating Supply Voltage (max)
27V
Operating Supply Voltage (typ)
5/9/12/15/18/24V
Operating Supply Voltage (min)
4.5V
Package Type
DSO
Operating Temperature (max)
150C
Operating Temperature (min)
-40C
Operating Temperature Classification
Automotive
Mounting
Surface Mount
Pin Count
28
Lead Free Status / RoHS Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TLE6262G
Manufacturer:
INFINEON
Quantity:
2 930
Part Number:
TLE6262G
Manufacturer:
INFINEON
Quantity:
32 120
Part Number:
TLE6262G
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Final Data TLE 6262 G
CAN Transceiver
The TLE 6262 is optimized for low speed data transmission up to 125 kbaud in
automotive applications. Normally a differential signal is transmitted or received
respectively. When a bus wiring failure (see table 4) is detected the device automatically
switches to a dedicated CANH or CANL single-wire mode to maintain the communication
if necessary. Therefore it is equipped with one differential receiver and four single ended
comparators (two for each bus line). To avoid false triggering by external RF influences
the single wire modes are activated after a certain delay time. As soon as the bus failure
disappears the transceiver switches back to differential mode after another time delay.
The bus failures are monitored via the diagnosis protocol of the SPI. Therefore it is
possible to distinguish 6 CAN bus failures or failure groups on the bits 8 to 13 (see table
3).
To reduce EMC caused by the transceiver the dynamic slopes of the CANL and CANH
signals are both limited and symmetric. This allows the use of an unshielded twisted or
parallel pair of wires for the bus. During single-wire transmission (bus-failure) the EMC
performance of the system is degraded from the differential mode.
The differential receiver threshold is set to typ. -2.8 V. This ensures correct reception in
the normal operation mode as well as in the failure cases 1, 2, 3a and 4 with a noise
margin as high as possible. When one of the bus failures 3, 5, 6, 6a, and 7 is detected,
the defective bus wire is disabled by switching off the affected bus termination and output
stage.
The CAN-transceiver offers three different operation modes that are controlled via the
SPI: the normal operation mode, Receive-only mode and V
stand-by mode. Please
bat
see the state diagram (figure 3). In the V
stand-by mode the RTL output voltage is
bat
switched to V
.
S
In case of a wake-up via the bus lines or one of the bus lines respectively, the TLE 6262
automatically sets the RxD output LOW. To send respectively receive messages the
CAN-transceiver can now be set in normal operation mode or receive-only mode by the
microcontroller.
When a reset occurs the transceiver circuit is automatically switched to V
-stand-by
bat
mode because the SPI input bits are automatically set LOW for this event.
A thermal shutdown of the CAN-transceiver circuit is monitored via the SPI diagnosis
bit 15.