40IMX1515158G POWER ONE, 40IMX1515158G Datasheet

no-image

40IMX1515158G

Manufacturer Part Number
40IMX1515158G
Description
Manufacturer
POWER ONE
Type
Step Downr
Datasheet

Specifications of 40IMX1515158G

Output Current
0.5(Typ) A
Output Voltage
15 V
Input Voltage
20 V
Number Of Outputs
2
Output Power
15(Typ) W
Switching Regulator
Yes
Table of Contents
Description
The IMX15, IMS15, and IMY15 Series of board mountable 15-
Watt DC-DC converters have been designed according to the
latest industry requirements and standards. The converters
are particularly suitable for use in mobile or stationary
applications in transport, railways, industry, or telecommu-
nications, where variable input voltages or high transient
voltages are prevalent.
Covering a total input voltage range from 8.4 up to 150 V with
different models, the converters are available with single and
electrically-isolated double outputs from 3.3 up to 48 V,
externally adjustable, with flexible load distribution on double-
output models. A shutdown input allows remote on/off.
Features include efficient input and output filtering and
consistently high efficiency over the entire input voltage range,
high reliability, and excellent dynamic response to load and
line changes.
The converters have been approved by TÜV and UL. Models
20IMS15/20IMX15 and 40IMS/40IMX15 provide supplemen-
tary insulation. Connected to a secondary circuit these models
provide SELV outputs, even if the bus voltage at the converter
BCD20008-G Rev AB, 26-Feb-09
Description ........................................................................... 1
Model Selection ................................................................... 2
Functional Description ......................................................... 4
Electrical Input Data ............................................................. 5
Electrical Output Data .......................................................... 8
Auxiliary Functions ............................................................. 13
®
40.6
1.6"
51
2.0"
IMX15/IMS15/ IMY15 DC-DC Series Data Sheet
Page
10.5
0.42"
Page 1 of 20
Features
input exceeds the SELV-limit of 60 VDC. The 110IMY15
models provide double insulation and are CE marked. They
may be connected to a rectified 110 VAC source without any
further isolation barrier.
The circuitry is comprised of integrated planar magnetics. All
components are automatically assembled and solidly soldered
onto a single PCB without any wire connection. Magnetic
feedback ensures maximum reliability and repeatability in the
control
consideration of possible thermal stress ensures the absence
of hot spots providing long life in environments, where
temperature cycles are frequent. The thermal design allows
operation at full load up to an ambient temperature of 85 °C in
free air without using any potting material. For extremely high
vibration environments the case has holes for screw mounting.
Electromagnetic Compatibility (EMC) ................................ 14
Immunity to Environmental Conditions .............................. 16
Mechanical Data ................................................................ 17
Safety and Installation Instructions .................................... 18
Description of Options ....................................................... 19
EC Declaration of Conformity ............................................ 20
• RoHS lead-free-solder and lead-solder-exempted
• Wide input voltage ranges up to 150 VDC
• 1 or 2 isolated outputs up to 48 V
• 1200 to 3000 VAC I/O electric strength test
• Emissions EN 55022 level A
• Immunity to IEC/EN 61000-4-2,-3,-4,-5, and -6
• High efficiency (typ. 87%)
• Input undervoltage lockout
• Shutdown input, adjustable output voltages
• Flex power: Flexible load distribution on outputs
• Outputs no-load, overload, and short-circuit proof
• Operating ambient temperature –40 to 85 °C
• Thermal protection
• 2" x 1.6" case with 10.5 mm profile
• Supplementary insulation: 20/40IMX15 models
• Double or reinforced insulation: 110IMY15 models
Safety according to UL/CSA 60950 -1
products are available.
loop
over
15 -Watt DC-DC Converters
all
operating
www.power-one.com
conditions.
1
110IMY15
models
1
Careful
Page

Related parts for 40IMX1515158G

40IMX1515158G Summary of contents

Page 1

Description The IMX15, IMS15, and IMY15 Series of board mountable 15- Watt DC-DC converters have been designed according to the latest industry requirements and standards. The converters are particularly suitable for use in mobile or stationary applications in transport, ...

Page 2

Model Selection Table 1: Model Selection Output 1 Output nom o nom o nom o nom [VDC] [A] [VDC] [A] 3.3 4 3.3 4 3.3 4 ...

Page 3

This is an exception to Power-One's normal nomenclature to identify this type of product, since G is already used to designate products for higher output current fitted with a synchronous rectifier. As ...

Page 4

Functional Description The IMX15/IMS15/IMY15 Series DC-DC converters are magnetic feedback-controlled flyback converters using current mode PWM (Pulse Width Modulation). The -05- and -0503- output voltage models, as well as all double-output models fitted with option R, exhibit an active ...

Page 5

Electrical Input Data General conditions °C, unless T is specified. – – Shut-down pin left open-circuit. – Trim or R input left open-circuit. Table 2a: Input data of IMX15 and IMY15 models Input Characteristics ...

Page 6

Table 2b: Input Data of IMS15 models; general conditions as in table 2a Input Characteristics Input voltage range Nominal input voltage V i nom Repetitive surge voltage V i sur Converter Switch on t startup 2 ...

Page 7

Inrush Current The inrush current has been made as low as possible by choosing a very small input capacitance. A series resistor may be installed in the input line to further reduce this current ...

Page 8

Electrical Output Data We recommend connecting an external 1 μF ceramic capacitor across the output pins. General conditions: = 25°C, unless T is specified – – Shutdown pin and Trim or R pin left open-circuit (not ...

Page 9

Table 7b: Output data for -05-8R and -0503-8R models; general conditions as in table 7a Output Characteristics , V Output voltage Output current 1 20IMX nom 24IMS/48IMS 40IMX/110IMY , I Current ...

Page 10

Table 7c: Output data for double-output models; general conditions as in table 7a Output Characteristics Output 1 24IMS/48IMS V o1 other models Output 2 24IMS/48IMS V o2 other models 1 Output current 20IMX I o nom other models Current ...

Page 11

Thermal Considerations If a converter, mounted on a PCB, is located in free, quasi- stationary air (convection cooling) at the indicated maximum ambient temperature (see T A max specifications) and is operated at its nominal input voltage and output ...

Page 12

0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 A Fig versus I (typ.) of double-output models ( V), with o o both outputs in parallel ...

Page 13

Auxiliary Functions Shutdown Function The outputs of the converters may be enabled or disabled by means of a logic signal (TTL, CMOS, etc.) applied to the shut- down pin. If this function is not required, the shut-down pin should ...

Page 14

Adjustment by means of an external resistor R Programming of the output voltage by means of an external resistor R is possible within 100 to 105 ext should be connected between the Trim pin and Vi–. ...

Page 15

Conducted Emissions PMM 8000 PLUS Date: 24.04.06 dbµV Name: 20d12_1 20IMX15-12-12-8 Peak 0.2 0 Fig. 17a Typ. disturbance voltage (peak) at pos. input according to EN 55011/022, measured at V and I ...

Page 16

Immunity to Environmental Conditions Table 12: Mechanical and climatic stress Test Method Standard Cab Damp heat IEC/EN 60068-2-78 steady state MIL-STD-810D sect. 507 Shock IEC/EN 60068-2-27 (half-sinusoidal) MIL-STD-810D sect. 516.3 Eb Bump IEC/EN 60068-2-29 (half-sinusoidal) MIL-STD-810D sect. ...

Page 17

Mechanical Data Dimensions in mm. Fig. 20 Case IMX15, IMS15, IMY15 Weight: <35 g 10.5 (0.41") Fig. 21 Open frame (option Z) BCD20008-G Rev AB, 26-Feb-09 IMX15/IMS15/ IMY15 DC-DC Series Data Sheet 45.72 (1.8") 10.5 (0.41") 0.8 (0.03") 1 ...

Page 18

Safety and Installation Instructions Pin allocation Table 15: Pin allocation Pin Standard and Option Z single double -0503- 1 Vi+ Vi+ 2 Vi– Vi– Trim n. ...

Page 19

Description of Options Table 17: Survey of options Option Function of option -9 Temperature range NFND R R-input and magnetic feedback i Inhibit Z Open frame Option -9 versus -8 IMX15 and IMY15 models with -9 (not for new ...

Page 20

DC-DC converters carrying the CE-mark are in conformity with the provisions of the Low Voltage Directive (LVD) 73/23/EEC of the European Communities. Conformity with the directives is presumed by conformity with the ...

Related keywords