40IMX1515158G POWER ONE, 40IMX1515158G Datasheet
40IMX1515158G
Specifications of 40IMX1515158G
Related parts for 40IMX1515158G
40IMX1515158G Summary of contents
Page 1
Description The IMX15, IMS15, and IMY15 Series of board mountable 15- Watt DC-DC converters have been designed according to the latest industry requirements and standards. The converters are particularly suitable for use in mobile or stationary applications in transport, ...
Page 2
Model Selection Table 1: Model Selection Output 1 Output nom o nom o nom o nom [VDC] [A] [VDC] [A] 3.3 4 3.3 4 3.3 4 ...
Page 3
This is an exception to Power-One's normal nomenclature to identify this type of product, since G is already used to designate products for higher output current fitted with a synchronous rectifier. As ...
Page 4
Functional Description The IMX15/IMS15/IMY15 Series DC-DC converters are magnetic feedback-controlled flyback converters using current mode PWM (Pulse Width Modulation). The -05- and -0503- output voltage models, as well as all double-output models fitted with option R, exhibit an active ...
Page 5
Electrical Input Data General conditions °C, unless T is specified. – – Shut-down pin left open-circuit. – Trim or R input left open-circuit. Table 2a: Input data of IMX15 and IMY15 models Input Characteristics ...
Page 6
Table 2b: Input Data of IMS15 models; general conditions as in table 2a Input Characteristics Input voltage range Nominal input voltage V i nom Repetitive surge voltage V i sur Converter Switch on t startup 2 ...
Page 7
Inrush Current The inrush current has been made as low as possible by choosing a very small input capacitance. A series resistor may be installed in the input line to further reduce this current ...
Page 8
Electrical Output Data We recommend connecting an external 1 μF ceramic capacitor across the output pins. General conditions: = 25°C, unless T is specified – – Shutdown pin and Trim or R pin left open-circuit (not ...
Page 9
Table 7b: Output data for -05-8R and -0503-8R models; general conditions as in table 7a Output Characteristics , V Output voltage Output current 1 20IMX nom 24IMS/48IMS 40IMX/110IMY , I Current ...
Page 10
Table 7c: Output data for double-output models; general conditions as in table 7a Output Characteristics Output 1 24IMS/48IMS V o1 other models Output 2 24IMS/48IMS V o2 other models 1 Output current 20IMX I o nom other models Current ...
Page 11
Thermal Considerations If a converter, mounted on a PCB, is located in free, quasi- stationary air (convection cooling) at the indicated maximum ambient temperature (see T A max specifications) and is operated at its nominal input voltage and output ...
Page 12
0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 A Fig versus I (typ.) of double-output models ( V), with o o both outputs in parallel ...
Page 13
Auxiliary Functions Shutdown Function The outputs of the converters may be enabled or disabled by means of a logic signal (TTL, CMOS, etc.) applied to the shut- down pin. If this function is not required, the shut-down pin should ...
Page 14
Adjustment by means of an external resistor R Programming of the output voltage by means of an external resistor R is possible within 100 to 105 ext should be connected between the Trim pin and Vi–. ...
Page 15
Conducted Emissions PMM 8000 PLUS Date: 24.04.06 dbµV Name: 20d12_1 20IMX15-12-12-8 Peak 0.2 0 Fig. 17a Typ. disturbance voltage (peak) at pos. input according to EN 55011/022, measured at V and I ...
Page 16
Immunity to Environmental Conditions Table 12: Mechanical and climatic stress Test Method Standard Cab Damp heat IEC/EN 60068-2-78 steady state MIL-STD-810D sect. 507 Shock IEC/EN 60068-2-27 (half-sinusoidal) MIL-STD-810D sect. 516.3 Eb Bump IEC/EN 60068-2-29 (half-sinusoidal) MIL-STD-810D sect. ...
Page 17
Mechanical Data Dimensions in mm. Fig. 20 Case IMX15, IMS15, IMY15 Weight: <35 g 10.5 (0.41") Fig. 21 Open frame (option Z) BCD20008-G Rev AB, 26-Feb-09 IMX15/IMS15/ IMY15 DC-DC Series Data Sheet 45.72 (1.8") 10.5 (0.41") 0.8 (0.03") 1 ...
Page 18
Safety and Installation Instructions Pin allocation Table 15: Pin allocation Pin Standard and Option Z single double -0503- 1 Vi+ Vi+ 2 Vi– Vi– Trim n. ...
Page 19
Description of Options Table 17: Survey of options Option Function of option -9 Temperature range NFND R R-input and magnetic feedback i Inhibit Z Open frame Option -9 versus -8 IMX15 and IMY15 models with -9 (not for new ...
Page 20
DC-DC converters carrying the CE-mark are in conformity with the provisions of the Low Voltage Directive (LVD) 73/23/EEC of the European Communities. Conformity with the directives is presumed by conformity with the ...