PFC250-1005 POWER ONE, PFC250-1005 Datasheet - Page 4

Linear & Switching Power Supplies 250W 5V 50A

PFC250-1005

Manufacturer Part Number
PFC250-1005
Description
Linear & Switching Power Supplies 250W 5V 50A
Manufacturer
POWER ONE
Type
Open Framer
Datasheet

Specifications of PFC250-1005

Output Current (max)
50A
Input Voltage
85 to 264V
Output Voltage
5V
Number Of Outputs
1
Output Power (max)
250W
Input Frequency
47 to 63Hz
Efficiency
75%
Screening Level
Commercial
Product Length (mm)
215.9mm
Product Height (mm)
50.8mm
Product Depth (mm)
120.7mm
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
70C
Mounting Style
Screw
Pin Count
21
Product
Switching
Output Voltage (channel 1)
5 V
Output Current (channel 1)
50 A
Dimensions
215.9 mm L x 120.7 mm W x 50.8 mm H
Brand/series
PFC250 Series
Configuration
Open-Frame
Current, Output
50 A
Frequency, Operating
63 kHz (Max.)
Line Regulation
0.5 %
Load Regulation
0.8%
Mounting Type
Panel
Operation
Switching
Output
5 VDC @ 50 A
Power, Output
250 W
Primary Type
AC-DC
Special Features
PFC, Remote Sense
Standards
UL Listed, CSA Certified, TUV Approved, CE Marked
Temperature, Operating
0 to +50 °C
Time, Response
500 uS (Nom.)
Voltage, Input
85 to 264 VAC
Voltage, Output
5 VDC
Size
8.50" × 4.75" × 2.00"
Size With Fan Option
10.0" × 4.75" × 2.5"
Lead Free Status / RoHS Status
Not Compliant
Lead Free Status / RoHS Status
Not Compliant
MAY 26, 2006 revised to AUG 16, 2006
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical
components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of
the respective divisional president of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
Safety, Regulatory, and EMI Specifications
PARAMETER
Agency Approvals
Dielectric Withstand Voltage
Electromagnetic Interference
ESD Susceptibility
Radiated Susceptibility
EFT/Burst
Input Transient Protection
Insulation Resistance
Leakage Current
Environmental Specifications
PARAMETER
Altitude
Operating Temperature
Storage Temperature
Temperature Coefficient
Relative Humidity
Shock
Vibration
Options
DESCRIPTION
Metric Mounting
Fan
CONDITIONS/DESCRIPTION
UL1950.
CSA 22.2 NO. 234/950.
EN60950 (TÜV).
Input to Output per EN60950.
FCC CFR title 47 Part 15 Sub-Part B - Conducted.
EN55022 / CISPR 22 Conducted.
Per EN61000-4-2, level 4.
Per EN61000-4-3, level 3.
Per EN61000-4-4, level 4.
Per EN61000-4-5 level 3.
Input-to-Output.
Per EN60950, 264 VAC.
CONDITIONS/DESCRIPTION
Operating.
Non-Operating.
Derate linearly above 50°C by 2.5% per °C.
0°C to 70°C (after 15 minute warmup).
Non-Condensing.
Peak acceleration.
Random vibration, 10 Hz to 2 kHz, 3 axes.
NOTES
Add “M” as a suffix to the model number to order chassis with
M4 x 0.7 mounting inserts.
Add “F” as a suffix to the model number to order integral fan.
Adds 1.5” (38.1mm) to overall length and 0.5” (12.7mm) to height.
Page 4 of 5
PFC250 AC-DC Series Data Sheet
Line-to-Ground
Line-to-Line
At 100% load:
At 50% load:
(215.9mm x 120.7mm x 50.8mm)
(250.4mm x 120.7mm x 63.5mm)
2600
MIN
MIN
-55
± 4
10
B
B
8
1
2
0
5
10.00” x 4.75” x 2.50”
8.50" x 4.75" x 2.00"
SIZE IMPACT
Approved
± 0.02
NOM
NOM
10
www.power-one.com
± 0.05
1500
MAX
MAX
10k
40k
50
70
85
95
20
6
ASL Ft.
ASL Ft.
UNITS
Class
UNITS
%/°C
%RH
G
VDC
V/M
M
G
kV
kV
kV
°C
°C
°C
RMS
PK
A

Related parts for PFC250-1005