Datasheet

Specifications of MAP110-4200

Input Voltage
85 to 264V
Number Of Outputs
4
Mounting Style
Screw
Output Current (max)
5/4/1/2A
Output Voltage
12/24/-12/-5V
Output Power (max)
80W
Input Frequency
47 to 63Hz
Efficiency
80%
Screening Level
Commercial
Product Length (mm)
177.8mm
Product Height (mm)
50mm
Product Depth (mm)
109.2mm
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
70C
Pin Count
19
Product
Switching
Commercial/medical
Commercial
Output Power Rating
240 W
Output Voltage (channel 1)
12 V
Output Current (channel 1)
12 A, 20 A
Output Voltage (channel 2)
24 V
Output Current (channel 2)
5 A, 9 A
Output Voltage (channel 3)
- 12 V
Output Current (channel 3)
1 A, 1.5 A
Dimensions
7 in L x 4.3 in W x 1.97 in H
Brand/series
MAP110 Series
Configuration
Open-Frame
Current, Input
3.5 A (RMS) @ 85 VAC, 2.8 A (RMS) @ 110 VAC
Current, Leakage
750 μA (Max.)
Hold Time
40 mS (Min.) 50% Load, 20 mS (Min.) Full Load
Mounting Type
Panel
Operation
Switching
Output
-12 VDC @ 1/1.5 A, +5 VDC @ 2/2.5 A, +12 VDC @ 5/9 A, +24 VDC @ 4/4.5 A
Power, Output
80 W
Power, Rating
110 W (Continuous)
Primary Type
AC-DC
Special Features
Remote Sense
Temperature, Operating
50 °C
Voltage, Input
85 to 264 VAC
Voltage, Output
-12, +5, +12, +24 VDC
Voltage, Output 1
-5 V
Voltage, Output 2
-12 V
Voltage, Output 3
12 V
Voltage, Output 4
24 V
En61000-4-2 Esd Level 4 (8 Kv)
All Map Products
En61000-4-3 Radiated Level 3 (10 V/m)
All Map Products
Universal Input
90-132 VAC or 175-264 VAC
Lead Free Status / RoHS Status
Not Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Not Compliant
MCD10142 Rev. 1.0, 27-Jan-10
Output Specifications
PARAMETER
Efficiency
Minimum Loads
Ripple and Noise
Output Power
Overshoot / Undershoot
Regulation
Transient Response
Turn-on Delay
Turn-on Rise Time
Interface Signals and Internal Protection
PARAMETER
Overvoltage Protection
Overload Protection
Remote Sense
Input Power Fail
Warning
Overtemperature Protection
Safety, Regulatory, and EMI Specifications
PARAMETER
Agency Approvals
Dielectric Withstand Voltage
Electromagnetic
Interference,
Conducted
Input Transient Protection
Insulation Resistance
Leakage Current
NOTES: 1) Minimum load is required only to meet the regulation limits of V3 and V4. If V3 and V4 are unused, no minimum load is necessary.
2) The following units meet Class B: MAP110-1005, MAP110-4000/4011/4015/4200/4300.
CONDITIONS/DESCRIPTION
Full load, 230 VAC. Varies with distribution of loads among outputs.
Single output models.
Multiple output models, V1 + V2 (Note 1).
Full Load, 20 MHz Bandwidth.
Multiple output units with convection cooling.
Multiple output units with 200 LFM forced air cooling.
Output voltage overshoot/undershoot at turn-on.
Varies by output, regulation includes: line changes from 90-132
VAC or 175-264, changes in load starting at 20% load and changing
to 100% load.
Recovery time, to within 1% of initial set point due to a 50-100%
load change, 4% max. deviation. (Main output only on multiple output units).
Time required for initial output voltage stabilization.
Time required for output voltage to rise from 10% to 90%.
CONDITIONS/DESCRIPTION
Provided on single output models and the
main output of multiple output models.
Fully protected against output overload and short circuit.
Automatic recovery upon removal of overload condition.
Voltage drop compensated for at the load.
Option, TTL compatible logic signal. Time before regulation dropout due
to loss of input power at 110 VAC. Active low.
Option, system shutdown due to excessive internal temperature.
CONDITIONS/DESCRIPTION
UL1950.
CSA 22.2 No. 234/950.
EN60950 (TUV).
Input to Output.
FCC CFR title 47 part 15 sub-part B - conducted & radiated.
EN55022 / CISPR 22 conducted.
EN55022 / CISPR 22 radiated (Note 2).
EN61000-4-5 level 3.
Input to output.
Per EN60950, 264 VAC.
Page 3 of 5
MAP110 AC-DC Series Data Sheet
All other models.
MAP110-1005
MAP110-1012
MAP110-1024
MAP110-4200
MAP110-4300
2600
6.10
17.3
32.2
13.8
5.75
MIN
MIN
MIN
3.7
65
10
0
1
5
5
3
2
NOM
NOM
NOM
500
150
75
See Model Selection Chart.
See Model Selection Chart.
B
B
A
5
www.power-one.com
Approved.
7.20
20.2
37.8
16.2
4.35
6.75
MAX
MAX
MAX
110
200
250
750
80
80
20
0
1
Amps
Amps
Watts
Watts
UNITS
UNITS
UNITS
Class
VDC
Sec
M
mS
mV
mS
µS
kV
µA
%
%
V
V