Specifications of LWN1240-6EM1

Input Voltage
85 to 264V
Number Of Outputs
1
Input Frequency
47 to 65Hz
Screening Level
Commercial
Product Length (mm)
138mm
Product Height (mm)
128mm
Product Depth (mm)
113.6mm
Operating Temperature Min Deg. C
-40C
Operating Temperature Max Deg. C
60C
Mounting Style
Din-Rail
Pin Count
5
Lead Free Status / RoHS Status
Not Compliant
Description of Options
E designates LW models with improved EMC performance.
Refer to the EC Declaration of Conformity (last page). Feature
E is standard for new designs.
Single options D1, D2, D5, R are available (as single choice
options) on the AUX terminal (10), referenced to Vo–.
Option M1 and M2 designate a combination of several options
accessible via a D-SUB connector. Option M1 includes the
function SD (shutdown).
Single Options Using the AUX Pin
The connection is shown in the figure below. For the
description refer to Adjustment of V
Multiple Options M1 or M2 via D-SUB Connector
The option board is suitable for applications, where several
options are needed. Option M1 is standard for battery charger
models, option M2 is suitable for applications without battery or
for simple applications with battery.
BCD20020-G Rev AB1, 17-Nov-09
Fig. 20
Connection of adjust resistors or an external voltage source to
adjust the output voltage V
Table 15: Pin allocation of the 9 pin D-SUB connector
Pin
Note: In double-output models, the options D1, D5, R, and SD
concern only output 2.
1
2
3
Adjustment with
1
2
3
4
5
6
7
8
9
or Vo+
or Vo–
Vo2–
Vo2+
Do not connect GND1 (pin 1) with the neg. output (–)
Do not connect VCC (pin 3) with the positive output (+)
In double-output models, R, D1, D5, SD concern output 2 only.
AUX
Designation
GND1
R
VCC
D1
D5
SD
D-adj
D2
Sys-OK
11
10
9
8
7
6
5
4
3
2
1
2
1
ext
System okay (all outputs are okay)
Description
System ground / common signal return
R input
Positive supply voltage ( output 2)
Output voltage monitor V
Output 2 voltage monitor V
Shutdown
Adjustment of threshold values of D1 or D5
Input voltage monitor V
®
o
or V
3
3
o2
or Vo–
(option M1 or M2 not fitted)
Adjustment with
Vo2–
o
AUX
or V
11
10
o2
9
8
7
6
5
4
3
2
1
i low
(next section).
o low D1
o low D5
125, 250 Watt AC-DC and DC-DC DIN-Rail Converters
3
3
ext
+
ext
Page 21 of 25
D2: Input Voltage Monitor (Power Fail)
D2 monitors the input voltage V
VAC or 92 VDC, the D2 signal output is high impedance (open-
collector, max. 50 V).
When V
conducting: V
Monitor
Fig. 21
Option D2: Examples of relay
control to monitor a power failure.
Table 16a: Option board M1
Table 16b: Option board M2
Function
Function
D-adjust
or Vo+
Sys-OK
1
1
Vo2+
D-adj
AUX
D1
D2
D5
SD
D2
D5
R
In double-output models, only output 2 is concerned.
R
In double-output models, only output 2 is concerned.
11
10
i
9
8
7
6
5
4
3
2
1
is greater then said level, the signal output D2 is
Output voltage adjust
Output voltage monitor V
Output 2 voltage monitor
(battery deep discharged): V
System okay
Shutdown
Adjustment of trigger values D1 and D5
Output voltage adjust
(battery deep discharged): V
Adjustment of trigger values D1 and D5
Description
Input voltage monitor V
Description
Input voltage monitor V
Output voltage monitor
D2
+
< 1.5 V, I
1
or Vo+
D2 max
Vo2+
W Series Data Sheet
1
1
1
< 50 mA. D1: Output Voltage
i low
i low
i
11
10
. When V
9
8
7
6
5
4
3
2
1
o low D1
1
o low D5
o low D5
1
5
+
9
i
D-SUB
www.power-one.com
4
drops below 65±3
8
3
9
7
5
2
D-SUB
8
6
4
+
1
3
7
2
6
1

Related parts for LWN1240-6EM1