B32529-C 105-K169 EPCOS Inc, B32529-C 105-K169 Datasheet - Page 39

no-image

B32529-C 105-K169

Manufacturer Part Number
B32529-C 105-K169
Description
Manufacturer
EPCOS Inc
Datasheet

Specifications of B32529-C 105-K169

Lead Free Status / RoHS Status
Compliant
2
To determine whether the following solvents, often used to remove flux residues and other sub-
stances, are suitable for the capacitors described, refer to the table below:
Type
MKT
(uncoated)
MKT, MKP, MFP
(coated/boxed)
Even when suitable solvents are used, a reversible change of the electrical characteristics may
occur in uncoated capacitors immediately after they are washed. Thus it is always recommended
to dry the components (e.g. 4 h at 70 C) before they are subjected to subsequent electrical test-
ing.
Table A
Manufacturers' designations for trifluoro-trichloro-ethane-based cleaning solvents (selection)
Trifluoro-trichloro-
ethane
Freon TF
Frigen 113 TR
Arklone P
Kaltron 113 MDR
Flugene 113
Table B (worldwide banned substances)
Manufacturers' designations for unsuitable cleaning solvents (selection)
Mixtures of chlorinated hydrocarbons and ketones with fluorated hydrocarbons
Freon TMC; Freon TA; Freon TC
Arklone E
Kaltron 113 MDD; Kaltron 113 MDK
Flugene 113 CM
Please read Important notes
at the end of this document.
Cleaning
Mixtures of trifluoro-trichloro-ethane with ethanol and
isopropanol
Freon TE 35; Freon TP 35; Freon TES
Frigen 113 TR-E; Frigen 113 TR-P; Frigen TR-E 35
Arklone A; Arklone L; Arklone K
Kaltron 113 MDA; Kaltron 113 MDI; Kaltron 113 MDI 35
Flugene 113 E; Flugene 113 IPA
Ethanol,
isopropanol,
n-propanol
Suitable
n-propanol-water
mixtures,
water with surface
tension-reducing
tensides (neutral)
Unsuitable
Suitable
Page 39 of 46
General purpose (stacked/wound)
B32520 ... B32529
Solvent from
table A (see
next page)
In part suitable Unsuitable
Suitable
Manufacturer
Du Pont
Hoechst
ICI
Kali-Chemie
Rhone-Progil
Manufacturer
Du Pont
ICI
Kali-Chemie
Rhone-Progil
Solvent from
table B (see
next page)

Related parts for B32529-C 105-K169