24IMS7-24-24-9 POWER ONE, 24IMS7-24-24-9 Datasheet

no-image

24IMS7-24-24-9

Manufacturer Part Number
24IMS7-24-24-9
Description
Module DC-DC 2-OUT 24V 0.15A 7.2W 9-Pin
Manufacturer
POWER ONE
Datasheet

Specifications of 24IMS7-24-24-9

Output Current
0.15(Typ) A
Output Voltage
24 V
Number Of Outputs
2
Output Power
7.2(Typ) W
Switching Regulator
Yes
Table of Contents
BCD20007-G Rev AD, 4-Nov-09
Description
The IMX7/IMS7 Series of board-mountable 7 Watt DC-DC
converters have been designed according to the latest industry
requirements and standards. The converters are particularly
suitable for use in mobile or stationary applications in
transport, railways, industry, or telecom, where variable input
voltages or high transient voltages are prevailent.
Covering a total input voltage range from 8.4 V to 150 V with
six different models, the converters are available with single
and electrically-isolated double outputs from 3.3 up to 48 V
with flexible load distribution on double outputs. A shutdown
input allows remote on/off.
Features include efficient input and output filtering with good
transient and surge protection, low output ripple and noise,
consistently high efficiency over the entire input voltage range,
and high reliability as well as excellent dynamic response to
load and line changes.
The converters provide supplementary insulation with SELV
outputs as for instances required in battery-supported
systems, where the bus voltage may exceed the SELV limit of
Description ............................................................................. 1
Model Selection ..................................................................... 2
Functional Description ........................................................... 3
Electrical Input Data ............................................................... 4
Electrical Output Data ............................................................ 7
Auxiliary Functions ................................................................. 9
®
25.4
1.0"
50.8
2.0"
10.5
0.42"
Page
Page 1 of 15
Features
60 V. The converters have been approved by UL. In addition,
70IMX7 and 110IMX7 models are CE-marked.
The circuitry is comprised of integral planar magnetics. All
components are automatically assembled and securely
soldered onto a single PCB without any wire connections.
Magnetic
repeatability in the control loop over all operating conditions.
Careful considerations of possible thermal stresses ensure the
absence of hot spots, providing long life in environments,
where temperature cycles are a reality. The thermal design
allows operation at full load up to an ambient temperature of
85 °C in free air without using any potting material. For
extremely high vibration environments the case has holes for
screw mounting.
Several options, such as open-frame, provide a high level of
application-specific engineering and design-in flexibility.
Electromagnetic Compatibility (EMC) .................................. 11
Immunity to Environmental Conditions ................................ 12
Mechanical Data .................................................................. 13
Safety and Installation Instructions ...................................... 13
Description of Options ......................................................... 14
EC Declaration of Conformity .............................................. 15
• RoHS lead-free-solder and lead-solder-exempted
• Input voltage ranges up to 150 VDC
• 1 or 2 isolated outputs up to 48 V
• 1200 to 2000 VAC I/O electric strength test
• Extremely wide input voltage ranges
• Immunity according to IEC/EN 61000-4-2, -3, -4, -5, -6
• High efficiency (typ. 84%)
• Input undervoltage lockout
• Inhibit input, adjustable output voltages
• Flex power: flexible load distribution on outputs
• Outputs no-load, overload, and short-circuit proof
• High reliability and no derating
• Operating ambient temperature – 40 to +85 °C
• Thermal protection
• Supplementary insulation
• 2” × 1” case with 10.5 mm profile
Safety according to IEC/EN 60950 and UL 60950
products are available.
IMX7/IMS7 DC-DC Series Data Sheet
feedback
7-Watt DC-DC Converters
ensures
maximum
www.power-one.com
1
70/110IMX7 models
reliability
Page
1
and

Related parts for 24IMS7-24-24-9

24IMS7-24-24-9 Summary of contents

Page 1

Description The IMX7/IMS7 Series of board-mountable 7 Watt DC-DC converters have been designed according to the latest industry requirements and standards. The converters are particularly suitable for use in mobile or stationary applications in transport, railways, industry, or telecom, ...

Page 2

... V. i min www.power-one.com 2 Options ...

Page 3

Part Number Description Input voltage range V i 8.4 – .............................................. 20 14 – ............................................... 24 16.8 – ............................................ 40 36 – ............................................... 48 40 – 121 V ............................................. 70 60 ...

Page 4

Electrical Input Data General conditions: – °C, unless T is specified – Connector pin i connected with Vi–. – Trim or R input not connected. Table 2a: Input data of IMX7 Input Characteristics Conditions ...

Page 5

... Measured with a lead length of 0.1 m, leads twisted. Double-output models with both outputs in parallel. 70/110 IMX7 models need an external capacitor at the input, e.g film or ceramic. 4 Source impedance according to ETS 300132-2, version 4. BCD20007-G Rev AD, 4-Nov-09 IMX7/IMS7 DC-DC Series Data Sheet 24IMS7 min typ – max = 0 – ...

Page 6

... The suppressor diode on the input also provides for reverse polarity protection by conducting current in the reverse direction, thus protecting the converter. An external fuse is required to limit this current. We recommend for: Peak Pulse – 20IMX7 and 24IMS7 a fast 2 A (F2A) fuse Current – 40IMX7 and 48IMS7 a fast 1 A (F1A) fuse P I ...

Page 7

Electrical Output Data General conditions: – °C, unless T is specified – Pin i connected with Vi –; Trim or R input left open-circuit. Table 5a: Output data for single-output models Output Characteristics Conditions ...

Page 8

Thermal Considerations If the converter, mounted on a PCB, is located in free, quasi- stationary air (convection cooling) at the maximum ambient temperature T (see table Temperature specifications) and A max is operated at nominal input voltage and output ...

Page 9

Typical Performance Curves V [V] o1 13 11.5 11 0.05 0.10 0.15 0.20 Fig. 9 Cross load regulation (typ.) of double-output models (2 12 V). The ...

Page 10

Single-output models with R-input: The R input (pin 13) is referenced to the secondary side of the converter. Adjustment of the output voltage is possible by means of either an external resistor or a voltage source. 06131 Vi+ Vi– ...

Page 11

... Performance criterion normal operation, no deviation from specifications temporary deviation from specs possible 3 Valid for 24IMS7 and 48IMS7 4 External components required Trim pin open, i pin connected with Vi– 6 Corresponds to the railway standard EN 50121-3-2:2000, table 9.1 Electromagnetic Emissions PMM 8000 PLUS Date: 5 ...

Page 12

Date: 5.9.07 PMM 8000 PLUS dbμV Name: 110_7_05 110IMX7-05 0.2 0 Fig. 16c 110IMX7-05-8: Typical conducted emissions (peak) at the input at V and I according to EN 55011/22. Output i nom ...

Page 13

... Failure Rates Table 11: MTBF and device hours Model Standard 24IMS7-05-9 MIL-HDBK-217F 40IMX7-12-12-8 MIL-HDBK-217F Bellcore 40IMX7-05-05-8 Bellcore Mechanical Data Dimensions in mm. Weight: <20 g 4.6 (0.18") Fig case temperature T Case IMX7/IMS7 with standard pinout Fig. 19 Open-frame model (option Z) Safety and Installation Instructions ...

Page 14

... Pollution degree 2 environment • Connecting the input to a secondary circuit, which is subject to a maximum transient rating of - 1500 V for 20IMX7, 24IMS7, 40IMX7, 48IMS7 - 2000 V for 70IMX7 - 2500 V for 110IMX7. The converters are subject to manufacturing surveillance in accordance with the above mentioned standards. ...

Page 15

EC Declaration of Conformity declare under our sole responsibility that IMS/IMX7 Series DC-DC converters carrying the CE-mark are in conformity with the provisions of the Low Voltage Directive (LVD) 73/23/EEC of the European Communities. Conformity with the directives is ...