DS1200-3 ARTESYN, DS1200-3 Datasheet - Page 10

no-image

DS1200-3

Manufacturer Part Number
DS1200-3
Description
AC/DC Power Supply Single-OUT 12V 98.4A 1.2KW 30-Pin
Manufacturer
ARTESYN
Datasheet

Specifications of DS1200-3

Input Voltage
90 to 264 V
Output Voltage
12 V
Maximum Current Rating
15(rms) A
Maximum Output Current
98.4 A
Number Of Outputs
1
Maximum Output Power
1200 W
Efficiency
89(Min) %
Input Frequency
47 to 63 Hz
Operating Temperature
-10 to 70 °C
Protection Function Specification
Input Fusing
DS1200-3 series is equipped with an internal non user serviceable 16A High Rupturing Capacity (HRC) 250 Vac fuse to
IEC 127 for fault protection in both the L1 and L2 lines input.
Over Voltage / Under Voltage Protection (OVP / UVP)
The power supply latches off during output overvoltage with the AC line recycled to reset the latch.
OVP
UVP
Over Current Protection (OCP)
DS1200-3 series includes internal current limit circuitry to prevent damage in the event of overload or short circuit.
Recovery is automatic when the overload is removed, if the overload lasts for 1 second or less, and if it is less than or
equal to 150% of rated load. If the overload is > 150% of rated load, the power supply will latch off immediately. In
addition, if the overload fault is presented for longer than 1 second, the power supply will also latch off, requiring AC power
or PS_ON recycling to restart the power supply.
Parameter
V
3.3V Standby Output
Overvoltage
5V Standby Output
Overvoltage
Parameter
V
Parameter
V
3.3V Standby Output
Overcurrent
5V Standby Output
Overcurrent
O
O
O
Output Overvoltage
Output Undervoltage
Output Overcurrent
180-264 Vac
90-179 Vac
90-264 Vac
90-264 Vac
Voltage
Input
13.2
3.76
5.75
Min
Min
9.0
Nom
Nom
Min
118
6.6
4.4
98
/
/
/
/
Nom
Max
Max
14.4
4.30
6.50
10.8
/
/
/
/
147.6
122.4
Unit
Unit
Max
V
V
V
V
9
6
Unit
A
A
A
A
Rev.10.03.30_#0.1
DS1200-3 Series
Page 10

Related parts for DS1200-3