P87C51RC2FA NXP Semiconductors, P87C51RC2FA Datasheet - Page 20

no-image

P87C51RC2FA

Manufacturer Part Number
P87C51RC2FA
Description
MCU 8-Bit 87C 80C51 CISC 32KB EPROM 3.3V/5V 44-Pin PLCC Tube
Manufacturer
NXP Semiconductors
Datasheet

Specifications of P87C51RC2FA

Package
44PLCC
Device Core
80C51
Family Name
87C
Maximum Speed
33 MHz
Operating Supply Voltage
3.3|5 V
Data Bus Width
8 Bit
Number Of Programmable I/os
32
Interface Type
UART
Number Of Timers
3
Ram Size
512 Byte
Program Memory Size
32 KB
Program Memory Type
EPROM
Operating Temperature
-40 to 85 °C

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
P87C51RC2FA
Manufacturer:
XILINX
Quantity:
101
Part Number:
P87C51RC2FA,512
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Part Number:
P87C51RC2FA512
Manufacturer:
NXP Semiconductors
Quantity:
1 909
Part Number:
P87C51RC2FAЈ¬512
Manufacturer:
PH3
Quantity:
1 066
When Timer 2 is in the baud rate generator mode, one should not try
1. Capture/reload occurs only on timer/counter overflow.
2. Capture/reload occurs on timer/counter overflow and a 1-to-0 transition on T2EX (P1.1) pin except when Timer 2 is used in the baud rate
Philips Semiconductors
to read or write TH2 and TL2. As a baud rate generator, Timer 2 is
incremented every state time (osc/2) or asynchronously from pin T2;
under these conditions, a read or write of TH2 or TL2 may not be
accurate. The RCAP2 registers may be read, but should not be
written to, because a write might overlap a reload and cause write
and/or reload errors. The timer should be turned off (clear TR2)
before accessing the Timer 2 or RCAP2 registers.
Table 4 shows commonly used baud rates and how they can be
obtained from Timer 2.
Summary of Baud Rate Equations
Timer 2 is in baud rate generating mode. If Timer 2 is being clocked
through pin T2 (P1.0) the baud rate is:
Table 5.
Table 6.
NOTES:
2003 Jan 24
80C51 8-bit microcontroller family
with 512B/1KB RAM, low voltage (2.7 to 5.5 V), low power, high
speed (30/33 MHz)
16-bit Auto-Reload
16-bit Capture
Baud rate generator receive and transmit same baud rate
Receive only
Transmit only
16-bit
Auto-Reload
generator mode.
Baud Rate + Timer 2 Overflow Rate
Timer 2 as a Timer
Timer 2 as a Counter
16
MODE
MODE
8KB/16KB/32KB/64KB OTP
20
Except for the baud rate generator mode, the values given for T2CON
If Timer 2 is being clocked internally, the baud rate is:
Where f
To obtain the reload value for RCAP2H and RCAP2L, the above
equation can be rewritten as:
Timer/Counter 2 Set-up
do not include the setting of the TR2 bit. Therefore, bit TR2 must be
set, separately, to turn the timer on. see Table 5 for set-up of Timer 2
as a timer. Also see Table 6 for set-up of Timer 2 as a counter.
INTERNAL CONTROL
INTERNAL CONTROL
Baud Rate +
RCAP2H, RCAP2L + 65536 *
(Note 1)
(Note 1)
OSC
00H
01H
34H
24H
14H
02H
03H
= Oscillator Frequency
P87C51RA2/RB2/RC2/RD2
[ n *
* n =
[65536 * (RCAP2H, RCAP2L)]]
T2CON
TMOD
16 in 6-clock mode
32 in 12-clock mode
f
OSC
EXTERNAL CONTROL
EXTERNAL CONTROL
n *
Baud Rate
f
OSC
(Note 2)
(Note 2)
0AH
0BH
08H
09H
36H
26H
16H
Product data

Related parts for P87C51RC2FA