120-8552-002 ITT Interconnect Solutions, 120-8552-002 Datasheet - Page 24

no-image

120-8552-002

Manufacturer Part Number
120-8552-002
Description
Connector Accessories Sure Seal For Plug 4 POS Black
Manufacturer
ITT Interconnect Solutions
Type
Sealr
Datasheet
SURE-SEAL
Wiring Instructions
Stripping lengths
For jacketed cables the following stripping lengths have to be
adhered to.
Insertion contacts
SURE-SEAL connectors have a one-piece connector body made
of rubber. Contacts are inserted from the rear side. They may only
be inserted with the approved tools (refer to page 18-22).
Plug or receptacle must be sprayed with lubricating fluid before
contact insertion.
Approved lubricating fluid
Manual insertion
Isopropyl alcohol
Cleaning solvent HAKU 424, Chem. Fabrik Kluthe
Gottlieb-Daimier Straße 12, 6900 Heidelberg
Semi-automatic insertion
CBITG...and CBITS-...Hellerine (P. Hellermann, Siemensstr. 5,
2080 Pinneberg) for sprayer.
With hand insertion tools
Fasten supports (table, vice etc.)
An inclined position is recommended for easier assembly.
Note: Insert accessories (e. g. Boot) prior to assembly.
Dip insulator in lubricating fluid and shake off excess fluid.
Open fixing clip and place connector body into support block
Insert cable resp. single wires into accessories (e. g. boot).
Pay attention to correct sequence and position
Install guiding pin CT317-8588-000 (does not apply to Mini
(refer to page 19).
SURE-SEAL) in socket contact.
No. of
contacts
2, 3, 4
5, 6, 7
8, 9, 10
min. stripping
lengths mm
40
45
50
Note: Socket or pin contacts have to be inserted into the correct
contact cavity.
Usage of jacketed cable with boot
Place contact in hand insertion tool. The contact shoulder has
Insert contact into the connector until it snaps in by applying
Remove guiding pins from the socket contacts!
Mount accessories.
Remove the terminated connector from support after
to touch the front side of the contact tip.
constant pressure. Note: Make sure that the contact and tool
are inserted parallel to the insulator axis. Do not tilt!
insertion of all contacts and check correct fit and position
of the contacts in the insulator (refer to page 18).
24
No. of contacts
2, 3, 4
5, 6, 7
Boot
Specifications and dimensions subject to change
Xmax
X max.
22
26
Connector
Dimensions shown in mm
www.ittcannon.com