HI1-0201HS/883 Intersil, HI1-0201HS/883 Datasheet - Page 13

no-image

HI1-0201HS/883

Manufacturer Part Number
HI1-0201HS/883
Description
Analog Switch Quad SPST 16-Pin CDIP
Manufacturer
Intersil
Type
Analog Switchr
Datasheet

Specifications of HI1-0201HS/883

Package
16CDIP
Maximum On Resistance
50@±15V Ohm
Maximum High Level Output Current
25 mA
Maximum Turn-on Time
50@±15V ns
Switch Architecture
SPST
Power Supply Type
Dual

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HI1-0201HS/883
Manufacturer:
INTERSIL
Quantity:
1 520
Part Number:
HI1-0201HS/883
Quantity:
287
DSCC FORM 2234
APR 97
approved alternatives shall be as specified in the device manufacturer's QM plan in accordance with MIL-PRF-38535. The test
circuit shall be maintained under document revision level control by the device manufacturer's TRB in accordance with
MIL-PRF-38535 and shall be made available to the acquiring or preparing activity upon request. The test circuit shall specify the
inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in test method 1005 of MIL-
STD-883.
(see 3.5 herein).
and V or MIL-PRF-38535, appendix A for device class M.
equipment), design applications, and logistics purposes.
prepared specification or drawing.
individual documents. This coordination will be accomplished using DD Form 1692, Engineering Change Proposal.
requires configuration control and which SMD's are applicable to that system. DSCC will maintain a record of users and this list will
be used for coordination and distribution of changes to the drawings. Users of drawings covering microelectronic devices (FSC
5962) should contact DSCC-VA, telephone (614) 692-0525.
692-0547.
MIL-PRF-38535 and MIL-HDBK-1331.
The vendors listed in QML-38535 have submitted a certificate of compliance (see 3.6 herein) to DSCC-VA and have agreed to this
drawing.
vendors listed in MIL-HDBK-103 have agreed to this drawing and a certificate of compliance (see 3.6 herein) has been submitted to
and accepted by DSCC-VA.
4.4.2.2 Additional criteria for device classes Q and V. The steady-state life test duration, test condition and test temperature, or
4.4.3 Group D inspection. The group D inspection end-point electrical parameters shall be as specified in table IIA herein.
4.4.4 Group E inspection. Group E inspection is required only for parts intended to be marked as radiation hardness assured
5. PACKAGING
5.1 Packaging requirements. The requirements for packaging shall be in accordance with MIL-PRF-38535 for device classes Q
6. NOTES
6.1 Intended use. Microcircuits conforming to this drawing are intended for use for Government microcircuit applications (original
6.1.1 Replaceability. Microcircuits covered by this drawing will replace the same generic device covered by a contractor-
6.2 Configuration control of SMD's. All proposed changes to existing SMD's will be coordinated with the users of record for the
6.3 Record of users. Military and industrial users should inform Defense Supply Center Columbus when a system application
6.4 Comments. Comments on this drawing should be directed to DSCC-VA, Columbus, Ohio 43216-5000, or telephone (614)
6.5 Abbreviations, symbols, and definitions. The abbreviations, symbols, and definitions used herein are defined in
6.6 Sources of supply.
6.6.1 Sources of supply for device classes Q and V. Sources of supply for device classes Q and V are listed in QML-38535.
6.6.2 Approved sources of supply for device class M. Approved sources of supply for class M are listed in MIL-HDBK-103. The
a.
b.
c.
End-point electrical parameters shall be as specified in table IIA herein.
For device classes Q and V, the devices or test vehicle shall be subjected to radiation hardness assured tests as specified
in MIL-PRF-38535 for the RHA level being tested. For device class M, the devices shall be subjected to radiation hardness
assured tests as specified in MIL-PRF-38535, appendix A for the RHA level being tested. All device classes must meet the
postirradiation end-point electrical parameter limits as defined in table I at
T
When specified in the purchase order or contract, a copy of the RHA delta limits shall be supplied.
DEFENSE SUPPLY CENTER COLUMBUS
A
= +25 C 5 C, after exposure, to the subgroups specified in table IIA herein.
MICROCIRCUIT DRAWING
COLUMBUS, OHIO 43216-5000
STANDARD
SIZE
A
REVISION LEVEL
D
SHEET
5962-86716
13