U1161A AGILENT TECHNOLOGIES, U1161A Datasheet - Page 7

Extended Test Lead Kit

U1161A

Manufacturer Part Number
U1161A
Description
Extended Test Lead Kit
Manufacturer
AGILENT TECHNOLOGIES
Datasheet

Specifications of U1161A

Voltage Rating
1000V
Kit Contents
Set Contents
Current Rating
15A
Lead Free Status / RoHS Status
na
[1] Input impedance: Refer to Table A on page 9.
[2] Crest factor ≤ 3.0 at full scale, 5.0 at half scale except the 1000 mV and 1000 V ranges where it is 1.5 at full scale, 3.0 at half scale.
[3] The additional error to be added as frequency >20 kHz and signal input <10% of range: 3 counts of LSD per kHz.
[4] The additional error to be added as frequency >15 kHz and signal input <10% of range: 3 counts of LSD per kHz.
[5] For U1252A / U1253A, the input signal is lower than 20,000,000 V-Hz (the product of voltage and frequency).
[6] Input current >35 µArms.
[7] Current can be measured from 2.5 A up to 10 A continuously. An additional 0.5% needs to be added to the specifi ed accuracy if the signal measured is in the range of 10 A ~ 20 A for 30
[8] Input current < 3 Arms.
[9] For non-square wave signals, add 5 counts.
[10] AC voltage and AC current specifi cations are true RMS AC coupled, valid from 5% to 100% of range.
U1252A/U1252B/U1253A/U1253B FREQUENCY SENSITIVITY DURING VOLTAGE MEASUREMENT
FREQUENCY SENSITIVITY DURING CURRENT MEASUREMENT
U1251A/U1251B FREQUENCY SENSITIVITY DURING VOLTAGE MEASUREMENT
For non-sinusoidal waveform, add 0.1% of reading ± 0.3% of range.
seconds maximum. After measuring a current of >10 A, leave the meter to cool down for twice the measuring time used before application of low current measurement.
accuracy = 10 x Range or 1000 V)
accuracy = 10 x Range or 1000 V)
(Maximum input for specifi ed
(Maximum input for specifi ed
INPUT RANGE
INPUT RANGE
INPUT RANGE
50.000 mA
440.00 mA
500.00 µA
5000.0 µA
50.000 mV
500.00 mV
1000.0 mV
50.000 mV
500.00 mV
1000.0 mV
5.0000 A
10.000 A
5.0000 V
50.000 V
500.00 V
1000.0 V
5.0000 V
50.000 V
500.00 V
1000.0 V
MINIMUM SENSITIVITY (R.M.S. Sine Wave)
20 Hz ~ 200 kHz
20 Hz - 100 kHz
30 V < 100 kHz
50 V < 100 kHz
120 mV
10 mV
25 mV
40 mV
0.25 V
10 mV
70 mV
2.5 V
0.3 V
25 V
50 V
3 V
FREQUENCY SENSITIVITY AND TRIGGER LEVEL
FREQUENCY SENSITIVITY AND TRIGGER LEVEL
MINIMUM SENSITIVITY
MINIMUM SENSITIVITY
20 Hz ~ 20 kHz
(R.M.S. Sine Wave)
(R.M.S. Sine Wave)
100 µA
250 µA
10 mA
25 mA
2.5 A
1 A
>100 kHz ~ 200 kHz
>200 kHz ~ 500 kHz
7
150 mV
300 mV
15 mV
35 mV
50 mV
25 mV
0.5 V
1.2 V
N/A
N/A
N/A
N/A
5 V
5 V
0.5 V / 1.25 V (< 100 Hz)
< 100 kHz
< 100 kHz
100 mV
120 mV
10 mV
60 mV
10 mV
70 mV
300 V
120 V
0.6 V
50 V
60 V
TRIGGER LEVEL FOR DC COUPLING
5 V
TRIGGER LEVEL FOR DC COUPLING
6 V
>100 kHz ~ 200 kHz
>100 kHz ~ 500 kHz
150 mV
150 mV
300 mV
15 mV
70 mV
25 mV
0.6 V
1.5 V
N/A
N/A
15 V
N/A