U1161A AGILENT TECHNOLOGIES, U1161A Datasheet - Page 12

Extended Test Lead Kit

U1161A

Manufacturer Part Number
U1161A
Description
Extended Test Lead Kit
Manufacturer
AGILENT TECHNOLOGIES
Datasheet

Specifications of U1161A

Voltage Rating
1000V
Kit Contents
Set Contents
Current Rating
15A
Lead Free Status / RoHS Status
na
U1163A SMT grabbers
• One pair of SMT grabbers (red and black).
• Rated CAT II 300 V, 3 A.
MEASURING ACCESSORIES (NON-TEMPERATURE)
U1168A Standard test lead kit
Includes two test leads (red and black), 19-mm and 4-mm test
probes, alligator clips, fi ne-tip test probes, SMT grabbers and
mini grabber (black).
• Test leads: CAT III 1000 V, CAT IV 600 V, 15 A
• Test probes (19-mm tip): CAT III 1000 V, CAT IV 600 V, 15 A
• Test probes (4-mm tip): CAT III 1000 V, CAT IV 600 V, 15 A
• Alligator clips: CAT III 1000 V, 10 A
• Fine-tip test probes: CAT II 300 V, 3 A
• SMT grabber: CAT II 300 V, 3 A
• Mini grabber: CAT II 300 V, 3 A
MEASURING ACCESSORIES (TEMPERATURE)
U1180A Thermocouple adapter+lead kit, J and K
types
Includes thermocouple adapter, thermocouple bead J-type and
thermocouple bead K-type.
• T/C adapter J/K-type
• T/C bead J-type: –20 °C to 200 °C
• T/C bead K-type: –20 °C to 200 °C
U1183A Air temperature probe
• Type-K T/C for use in air and non-caustic gas
• Measurement range: –50 ºC to 800 ºC
• Includes adapter U1184A for connection to DMM
(highly recommended for CAT IV environment)
Recommended for use with Agilent standard test leads.
U1164A Fine-tip test probes
• One pair of fi ne-tip test probes (red and black).
• Rated CAT II 300 V, 3 A.
U1169A Test probe leads
Includes two test leads (red and black), and a pair each of
19-mm and 4-mm test probes.
• Test leads: CAT III 1000 V, CAT IV 600 V, 15 A
• Test probes (19-mm tip): CAT III 1000 V, CAT IV 600 V, 15 A
• Test probes (4-mm tip): CAT III 1000 V, CAT IV 600 V, 15 A
U1181A Immersion temperature probe
• Type-K T/C for use in oil and other liquids
• Measurement range: –50 °C to 700 ºC
• Includes adapter U1184A for connection to DMM
U1184A Temperature probe adapter
• Mini-connector-to-banana-plug adapter for use with DMM
(highly recommended for CAT IV environment)
Recommended for use with Agilent standard test leads.
12
U1165A Test probe leads
• Rated CAT III 1000 V, 15 A
U1583B AC current clamp
• Dual range: 40 A and 400 A
• Rated CAT III 600 V
• BNC-to-banana-plug adapter provided for use with DMMs
U1182A Industrial surface temperature probe
• Type-K T/C for use on still surfaces
• Measurement range: –50 ºC to 400 ºC
• Includes adapter U1184A for connection to DMM
U1185A J-type thermocouple and adapter
• T/C adapter J/K-type
• T/C bead J-type: –20 °C to 200 °C