Bandwidth
350MHz
Counter Measuring Functions
Frequency, Period,Totalize, Ratio, Time Interval, Rise/Fall, Width, Burst Width, Duty Cycle, Phase, PRI, PRF
Lead Free Status / RoHS Status
na
Speed Characteristics
1. These Math operations do not apply for Continuous Totalize or Timestamp measurements.
2. Allan Deviation is only calculated for Frequency and Period measurements. Allan Deviation calculation is available on both 53220A
3. Limit Test only displays on instrument front panel. No hardware output signal is available.
4. Operating speeds are for a direct connection to a >2.5 GHz dual core CPU running Windows
5. Throughput data based on gate time. Typical reading throughput assumes ASCII format, Auto level OFF with READ? SCPI command. For
6. Maximum 53230A rates represent >= 20 MHz input signals with min gate times, no delays or holdoffs. Measurement rates for the
Maximum measurement speed to internal non-volatile memory
Timestamp
Frequency, period, totalize
Frequency ratio
Time interval, rise/fall,
width, burst width
Duty cycle
Phase
PRI, PRF
Transfer from memory to PC via:
LAN (sockets)
LAN (VXI-11)
USB
GPIB
and 53230A, it is only gap free on 53230A.
a 10/100/1000 LAN interface.
improved reading throughput you should also consider setting (FORM:DATA REAL,64), (DISP OFF), and set fastest gate time available.
53210A & 53220A are limited by min gate time. Actual meas rates are limited by the repetition rate of the input being measured.
4
(meas)
53210A
N/A
N/A
N/A
N/A
N/A
300
continued
12
6
600,000 readings/sec
150,000 readings/sec
800,000 readings/sec
: (readings/s)
22,000 readings/sec
53220A
1000
N/A
N/A
®
XP Pro SP3 or better with 4 GB RAM and
1,000,000
53230A
75,000
44,000
90,000
48,000
37,000
75,000