FLUKE-772 Fluke, FLUKE-772 Datasheet - Page 14

MULTIMETER, DIGITAL, CLAMP

FLUKE-772

Manufacturer Part Number
FLUKE-772
Description
MULTIMETER, DIGITAL, CLAMP
Manufacturer
Fluke
Datasheets

Specifications of FLUKE-772

Dmm Type
Clamp
Voltage Measuring Range Dc
0 To 30.00 V Dc
Current Measuring Range Dc
0mA To 100mA
Current Measuring Range Ac
0mA To 100mA
Dmm Functions
AC/DC Current
Current Ac Max
100mA
Ranging
Auto
Altitude
0 to 2000 m
Dimensions
1.63" × 3.0" × 9.75"
Humidity
<90% @ <30°C, <75% @ 30 to 55°C
Ip Rating
IP 40
Shock Resistance
1 m Drop Test (except jaw)
Temperature, Operating
-10 to 50 °C
Vibration
Random 2 g, 5 to 500 Hz
Lead Free Status / RoHS Status
na
Lead Free Status / RoHS Status
na
Electrical Specifications
Current Measurement
With Jaw
In Circuit
Current Source
Current Simulate
DC Voltage Measurement (773)
DC voltage source (773)
mA IN/OUT (773)
Scaled mA current output to mA current input from the Jaw (773)
Response speed ........................ 2 times per second
DC Loop Power.......................... 24 V
Influence of Earth’s Field............ <0.20 mA
Batteries..................................... 4 1.5 V, Alkaline , IEC LR6
Working hours ............................ 12 hours @ 12 mA sourced into 500
Mechanical Specifications
Size (H X W X L) ....................... 43.7 mm x 70 mm x 246.2 mm
Weight........................................ 410 g
Ranges ................................ 0-20.99 mA; 21-100 mA
Resolution............................ 0.01 mA; 0.1 mA
Accuracy.............................. 0.2 % + 5 counts;1 % + 5 counts
Range .................................. 0-24 mA
Resolution............................ 0.01 mA
Accuracy.............................. 0.2 % + 2 counts
Range .................................. 0-24 mA
Resolution............................ 0.01 mA
Accuracy.............................. 0.2 % + 2 counts
mA Drive.............................. 24 mA into 1000
Range .................................. 0-24 mA
Resolution............................ 0.01 mA
Accuracy.............................. 0.2 % + 2 counts
Maximum Voltage ................ 50 V
Range .................................. 0-30 V
Resolution............................ 0.01 V
Accuracy.............................. 0.2 % + 2 counts
Range .................................. 0-10 V
Resolution............................ 0.01 V
Accuracy.............................. 0.2 % + 2 counts
mA Drive.............................. 2 mA max all conditions
Sourcing range .................... 0-24 mA
Sourcing resolution .............. 0.01 mA
Sourcing accuracy ............... 0.2 % + 2 counts
Measurement range............. 0-24 mA
Measurement resolution ...... 0.01 mA
Measurement accuracy ....... 1 % FS
Range .................................. 0-24 mA
Resolution............................ 0.01 mA
Accuracy.............................. 1 % FS