FLUKE-355 Fluke, FLUKE-355 Datasheet - Page 3

MULTIMETER, DIGITAL, CLAMP, 4 DIGIT

FLUKE-355

Manufacturer Part Number
FLUKE-355
Description
MULTIMETER, DIGITAL, CLAMP, 4 DIGIT
Manufacturer
Fluke
Datasheets

Specifications of FLUKE-355

Dmm Type
Clamp
Voltage Measuring Range Dc
0V To 1000V
Voltage Measuring Range Ac
0V To 1000V
Current Measuring Range Dc
0A To 2000A
Current Measuring Range Ac
0A To 2000A
Lead Free Status / RoHS Status
na
Lead Free Status / RoHS Status
na
Continuity beeper (355 only)
On at ≤ 30 W
Off at ≥ 100 W
Frequency measurement
General specifications
Environmental specifications
Ordering information:
Fluke-353 AC/DC True-rms Clamp Meter, 2000 A, Amps only
Includes: C43 Soft Carrying Case, 6 AA batteries, and users manual
Fluke-355 AC/DC True-rms Clamp Meter, 2000 A
Includes: C43 Soft Carrying Case, 6 AA batteries, TL224 1.5 m
Silicone Rubber Test Leads, TP2 Test Probes, AC285 Alligator Clips,
and users manual
3 Fluke Corporation
Measurement range
Resolution
Accuracy – 5.0 Hz to 100 Hz
Accuracy – 100.1 Hz to 1 kHz
Trigger level
Batteries
Battery life (with typical usage, backlight off)
Test leads
Weight
Jaw size
Dimensions (LxWxD)
Safety rating
Operating temperature
Storage temperature
Operating humidity
Operating altitude
Storage altitude
IP rating
Drop test requirements
EMI, RFI, EMC
Temperature coefficients
Fluke 355/353 True-rms 2000 A Clamp Meters
Fluke-355
5.0 Hz to 1 kHz
0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz)
0.2 % + 2 counts
0.5 % + 5 counts
Refer to current and voltage tables
Six 1.5 V AA NEDA 15 A or IEC LR6
100 hours
Rated to 1000 V
.814 kg (1.8 lb)
58 mm (2.28 in)
300 mm x 98 mm x 52 mm (12 in x 3.75 in x 2 in)
IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III
32 °F to + 122 °F (0 °C to +50 °C)
-4 °F to 140 °F (-20 °C to +60 °C)
0 to 95 % (non-condensing)
2000 m
10,000 m
42 (indoor use only)
1 m
FCC part 15, IEC/EN 61326-1:1997 class B, IEC/EN
61326:1997 3V/m, performance criteria B, EN61325
Current: 0.1 % of reading per °C outside 22 °C to 24 °C
Voltage: 0.1 % of reading per °C outside 22 °C to 24 °C
Fluke-353