Specifications of 72-7730 CALIBRATED

Dmm Type
Handheld
Voltage Measuring Range Dc
200mV - 1000V
Voltage Measuring Range Ac
2V - 1000V
Current Measuring Range Dc
200µA To 10A
Current Measuring Range Ac
200µA To 10A
Lead Free Status / RoHS Status
na
Model 72-7730: OPERATING MANUAL
F. Measuring Capacitance
To ensure accuracy, the Meter inside is discharged
against the tested capacitor. “DIS.C” will be shown
on the display when it is under discharging, this
process will be quite slow.
To avoid damage to the Meter or to the equipment
under test, disconnect circuit power and discharge
all high-voltage capacitors before measuring
capacitance.
Use the DC Voltage function to confirm that the capacitor
is discharged.
To measure capacitance, set up the Meter as shown
in Figure 3-6 and proceed as follows:
1.
Insert the red test lead into the
black test lead into the COM terminal.
Warning
terminal and the
Figure 3-6. Capacitance Measurement
39