12211 Simpson, 12211 Datasheet - Page 8

no-image

12211

Manufacturer Part Number
12211
Description
MULTIMETER, ANALOG, 7 FUNCTIONS
Manufacturer
Simpson
Datasheet

Specifications of 12211

Voltage Measuring Range Dc
250mV To 1000V
Voltage Measuring Range Ac
2.5V To 1000V
Current Measuring Range Dc
50µA To 5A
Current Measuring Range Ac
250A
Range Selection
Manual
Accuracy
+/- 2 %
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
1.
2.
3.
4.
protection continues until the Instrument leads are disconnected (or until the cir-
cuit fault is cleared).
The 260-6XPLM is not protected from catastrophic type overloads where the dam-
age due to overloads occurs within the response time of the protective relay, or
from voltages above the maximum capability of the Instrument.
1.4
All accessories and supplies required for the operation of the 260 is furnished with
each instrument, and listed in Table 1-2.
1.5
Table 1-1 lists the technical specifications for the Simpson 260-6XLPM Volt-Ohm-
Milliammeter.
NOTE: Accuracy specifications apply to measurements made with the Instrument
in a horizontal position (meter facing upward). Reference Conditions: +25°C ±5°C;
45% to 75% relative humidity.
DC VOLTAGE
Ranges (full scale):
Accuracy:
Sensitivity:
AC VOLTAGE
Ranges (full scale):
Accuracy:
Sensitivity:
Frequency Response:
OHMS CONVENTIONAL
Ranges:
Ohms Center:
Max. Scale Reading:
Accuracy:
LOW POWER OHMS
Ranges:
Ohms Center:
Max. Scale Reading:
Accuracy:
Accessories and Supplies
Technical Data
Table 1-1. Technical Data
250 mV, 1.0V, 2.5V, 10V, 25V, 100V, 250V, 500V
and 1000V
20,000
2.5V, 10V, 25V, 100V, 250V, 500V and 1000V
5000
See curve in Figure 4-1
RX1, RX100, RX1k and RX10k
6, 600, 6000 and 60k
1000
±2.5° of an arc on the RX1 range; ±2.0° of arc on
all other ranges. The nominal open-circuit volt-
age for all ranges up to RX1k is 1.5V. The RX10k
range has an open circuit voltage of 9V. The maxi-
mum current drawn from the 1.5V battery is 250
mA (RX1 with test leads shorted).
RX1 and RX10
20 and 200
1000
±2.5° of arc. The maximum open circuit voltage
for the low power ohms ranges is 100 mV and the
maximum measuring power is 0.125 mW. The
battery quiescent current is 4.3 mA at RX1 and
0.43 mA at RX10.
±2% of full scale on all ranges
±3% of full scale on all ranges
!
8
/V
(RX1)
(RX1)
/V